Compatible Visible Spectrophotometer 

T3/T3M 

 

 
 
 
 
 
 
 
 
 
 

Operation Instruction Manual 

Содержание T3

Страница 1: ...Compatible Visible Spectrophotometer T3 T3M Operation Instruction Manual ...

Страница 2: ......

Страница 3: ...al products and is widely used in public health environmental protection life sciences industries and many other organic and biochemical applications For obtaining maximum performance and trouble free operation we give you the following suggestions Upon receiving your instrument please check all the items listed in the packing list are included and install the instrument according to the instructi...

Страница 4: ... the protection provided by the equipment may be impaired Avoid collision and handle the instrument carefully during transportation If the tested solution is harmful to humans please wear gloves or use other protection methods Please keep the accessories in a safe place for the use in future maintenance For more information please visit www perseena com ...

Страница 5: ...avoid pressing the touch screen forcibly Avoid blocking the exhaust fan avoid working in the high temperature environment In order to avoid destroying the instrument strong impact should be avoided Instrument should be placed in a stable working platform Strong vibration source should be avoided during the measurement Take some safety measure arrest the thunder when installing antenna in the wild ...

Страница 6: ...T3 T3M Instruction Manual 4 Instrument should be avoided working in strong electromagnetic environment Balance the energy after changing measurement assembly ...

Страница 7: ...ter 2 Main units 2 1 Main unit configuration 2 2 Test tube holder accessory 2 3 Cell holder accessory 2 4Main unit and interface introduction 2 5 Connection between the main unit and PC Accessories 2 6 Power supply monitor and battery charging Chapter 3 Measurement accessories instruction 3 1 Fiber probe 3 2 Using method Chapter 4 Operation 4 1 Instruction before using ...

Страница 8: ...easurement 4 2 5 Photometric measurement 4 2 6 Kinetics 4 2 7 Spectrum scanning 4 2 8 System settings 4 3 Video Chapter 5 T3 Data Viewer software installation and Operation 5 1 Software installation 5 1 1 T3 Data Viewer Installation steps 5 1 2 Installation of Microsoft Net Framework 2 0 5 1 3 Installation of Windows Mobile Device Center 5 1 4 Installation of USB drivers 5 2 Software operation ...

Страница 9: ...uction Manual 7 Chapter 6 Instrument maintenance 6 1 Maintenance cautions 6 2 Replacement of battery 6 3 Replacement of fiber probe and reflection mirror Chapter 7 Troubleshooting Chapter 8 Instrument Configuration ...

Страница 10: ...me detection The instrument is provides with the function of spectrum scanning kinetics quantitative measurement and photometric measurement so the application field of it is so wide The measuring method is based on the Lamber Beer s Law which is found on the absorption to light of the material 1 2 Structures The T3 system is consist of main unit cell holders test tube holders and fiber probe 1 3 ...

Страница 11: ...e adopts gathering micro tungsten lamp with the characteristics of small volume stable illumination and long life time which can meet the special requirements for portable devices 1 4 Functions and configuration Spectrum Scanning Photometric Measurement Kinetics food analysis water analysis video player and other user defined functions quantitative measurement The main unit can be operated stand a...

Страница 12: ...ent for 4 5 hours Configure with 100 240V 50Hz 60Hz charging power supply it can offer power for the main unit and charge the battery Offering micro printer optional configuration Offering box for carrying the instrument conveniently 1 5 Specification and performance Light Source Convergent tungsten lamp the life time is 7000 hours Measurement Mode Spectrum Quantitative Kinetics Photometric Monoch...

Страница 13: ...arger Printer Micro printer optional Operating system Embedded operation system integration 2G Flash memorizer With timing function Input display Large touch screen 320 240 lattice Specifications Wavelength range 380nm 800nm Data resolution 0 4nm Spectral bandwidth 4 0 8nm Wavelength accuracy 1 0 nm Wavelength repeatability 0 1nm Baseline flatness 0 005Abs Noise 0 5 Drift 1 0 Stray light 0 5 Photo...

Страница 14: ...Photometric repeatability 0 3 Dimension 280 170 110mm Environmental temperature Operation environment 5 30 Store environment 20 55 Chapter 2 Main units 2 1 Main unit configuration Figure 2 1 Main unit 2 2 Test tube holder accessory ...

Страница 15: ... hole insert theφ25 test tube into the test tube holder and the test tube is fixed by the spring Figure 2 2 φ25 Test tube holder accessory 2 φ16 test tube holder shown as figure 2 3 Insert the small test tube adapter into the test tube holder tighten the screws Insert theφ16 test tube into the adapter and the test tube is fixed by the spring ...

Страница 16: ...ry Cautions If choosing the special test tube with arrow label it s necessary to rotate for location after inserting the test tube into test tube holder The two arrows on test tube and test tube holder should be matched as figure 2 4 shown Figure 2 4 Test tube location ...

Страница 17: ... cuvettes The baffle and spring work together to fix the position of cuvettes assure the precision of measurement Installation 1 Put the cell holder into the sample compartment 2 Tighten the fixed screw 3 Insert the baffle and spring into the cell holder as the cuvettes dimensions 4 Clean the cuvettes after finishing measurement 5 Loose the fixed screw and remove the cell holder ...

Страница 18: ...T3 T3M Instruction Manual 16 Figure 2 6 Installation of cell holder ...

Страница 19: ...on the main unit and the instrument is running AC Plug Connecting with the charging power supply power for the main unit and charge the battery Charging indicator The indicator is lit when charging the main unit it is off Charger indicator AC plug SIM Card RS23 USB main interface Power switch USB slave interface LAN GPS interface ...

Страница 20: ...ash memory Also can connect with the USB printer USB slave interface Connect with the PC Download view export and print the data by the special software T3 data viewer SIM card Insert the SIM card for GPRS communication Here is the insert method of the SIM card as figure 2 8 shown Figure 2 8 SIM card insert method LAN Connect with the LAN for internet communication GPS interface Connect with the G...

Страница 21: ...the RS232 port while the other side is connected with the printer Print the data and spectrum directly by pressing Print button on different modules The communication method between the T3 and PC is the same as that mentioned above One side of the USB cable connected with the USB slave interface while the other side is connected with the PC the communication will be built after synchronization ...

Страница 22: ...T3 T3M Instruction Manual 20 Figure 2 9 RS232 port communication 2 6 Power supply monitor and battery charging Charge interface is connected as Figure 2 10 ...

Страница 23: ...T3 T3M Instruction Manual 21 Figure 2 10 Charging interface connection When the main unit is running it will display the battery volume on the right upper corner See figure 2 11 ...

Страница 24: ... main unit and charging the battery The charging power supply should be connected with AC of 100 240V 50 60Hz The other end is connected with the charging interface on the main unit The power supply indicator is lit The screen displays charging After the charging is finished the power supply indicator will be off The screen displays The standard charging time is 5 6 hours The ...

Страница 25: ...ow battery Chapter 3 Measurement accessories instruction Note The flexing diameter of the fiber should be bigger than 0 1 meter to avoid the inner fiber breaking Fix the fiber probe in the holder when measuring and keep it not moving 3 1 Fiber probe This instrument takes fiber probe to take photometric measurement Put the immerging fiber probe into the sample solution to measure Here are the ...

Страница 26: ...m Pathlength 10mm 20mm interchangeable Standard SMA 905 port Attached with holder easy to install on site The reflection mirror can be disassemble easy to clean The material of the fiber probe is titanium alloy which is acid and organic solvent resistant Figure 3 1 Fiber probe assembly ...

Страница 27: ...probe into holder Measurement choose the corresponding method put the fiber probe into a blank solution to do zero correction and sample to measure Clean the probe with a filter paper and wash with the solution to be test three times Note If there is bubble existing on the top of the probe after inserting into the solution please remove the tested solution and shake the handle gently The measureme...

Страница 28: ...ich are status bar navigation bar current page and tool bar See figure 4 1 Figure 4 1 Interface Status bar Shown on the left of the status bar are the current measurement mode and flash memory notice the choices are transmittance T Abs and Energy Es on the right is the current time and battery status Navigation bar Status bar Current page Tool bar ...

Страница 29: ...by pressing button Only on measurement page can switch to the other navigation pages Tool bar List the operation that can be carried on the Current page The chosen items character will be bold Taskbar A dynamic window pop up when a certain task is performed the window automatically disappears after the task is completed Click to abort the task and hide the window There are also the buttons as foll...

Страница 30: ...row the following option box click the option you need Figure 4 2 If there is in the option box click it will pop up the input panel by which the user can customize the option Input edit box If you want to change the content in the input box click the content on the right the program will automatically detect the content input and a corresponding number or text input panel will pop up for user to ...

Страница 31: ... Figure 4 4 Figure 4 3 is the numerical input panel Figure 4 4 is the text input panel For Figure 4 3 0 9 Numerical input keys Enter the decimal point Clear the input re enter Delete the data in front of Save the original data value and exit ...

Страница 32: ... input and exit For Figure 4 4 26 letters Shift the input methods among characters numbers and PinYin Space Next line Delete the date in front Previous line Save the new input and exit Save the original data value and exit Spectrum Processing ...

Страница 33: ...Instruction Manual 31 If the main page is spectrum double click the spectrum a spectrum processing box will pop up as follows Figure 4 4 The functions of the buttons are as follows Zoom in Zoom out Peak search ...

Страница 34: ...oordinates Distance measuring positioning by dragging the acute angle of the triangle Read the point value on the spectrum if click this button use the arrow moving from left to right to select the date point Select the area of interest Move the whole processing panel Exit the spectrum processing ...

Страница 35: ...ou to put in the blank solution Figure 4 6 Then press the button OK the following taskbar will pop up Figure 4 7 Step two if the Auto Zero is successful the taskbar will disappear automatically 4 1 3 Sample Measurement After the auto aero is finished put in the solution you want test click measure on the main page a taskbar measuring will pop up Click to abort the measurement The taskbar will hide...

Страница 36: ...ce Switch on the mainframe the main interface see Figure 4 8 will display after the boot screen Figure 4 8 Eight functions of this unit food analysis water analysis quantitative measurement spectrum scanning photometric measurement kinetics scanning system settings and method videos This unit is touch screen control press the key areas with touch pen or mouse ...

Страница 37: ...itrite sulfur dioxide formaldehyde cyanide and peroxide value etc User can also customize dedicated test methods under quantitative measurement mode Ordinary procedure of food safety select measuring methods select measuring module measure sample save data check data print data Refer to instruction manual of food safety analysis for more information Fig4 9 is the method selection interface of food...

Страница 38: ...ethod the description characters of this method will turn into deep color click start measuring at first it will remind you to choose appropriate measurement modules see fig 4 10 Figure 4 10 Click OK enter into the measurement interface shown in fig 4 11 ...

Страница 39: ...he measuring interface to measure after zeroing Start begin to measure Press Measure the system will carry out the real time measuring Save Save the measuring results Press Save a text box will pop up in which the user can input the name of the data If GPRS is on the data the relevant information will be uploaded in the mean time Timer start the predefined timer Exit back to the main page ...

Страница 40: ...e the test as a baseline for measurement Click the on the navigation bar to set the parameters The interface as Figure 4 12 will pop up which consist of parameter option page and instrument option page Parameter Setting Page Figure 4 12 The options can be set up are Coefficient Input the factors of the calibration curve different factors for different methods ...

Страница 41: ... upper and lower limits of concentration of this method Timers Count modify the number of timers and the time for them Significant figure number of significant digits displayed Instrument Setting Page Figure 4 13 Average times can be selected from 1 2 4 8 to 16 ...

Страница 42: ...ction Manual 40 Lamp Setting page Figure 4 14 Lamp on Lamp off set the status of the lamp Energy balance adjust the energy of tungsten lam After changing measurement assembly click this button to satisfy requirement ...

Страница 43: ... Figure 4 15 Sample Ent set the company of sample belongs to Sample Name set the name of measured sample Operator set the name of operator Enter the calibration standards page by clicking the button on the navigation bar then measure the standard sample ...

Страница 44: ...T3 T3M Instruction Manual 42 Figure 4 16 Add add a new standard sample you will first input the concentration of the standard sample as figure 4 17 shown ...

Страница 45: ...nd save Return return to the setting interface By shift between Standard and Curve can view the related data and fitting information See Figure 4 18 for the standard curve Note in case the first order curve is used at least two sets of standard samples should be measured in case quadratic curve is used at least three sets of standard samples should be measured ...

Страница 46: ...T3 T3M Instruction Manual 44 Figure 4 18 Curve Click the button in the navigation bar on the measurement interface can view the previous measuring results corresponding to the current method ...

Страница 47: ... all is selected the current option will be None which can clear the options Export insert the flash memory into the USB slot the user can export the data to it Upload upload the chosen data to the server Besides description should be added for the pesticide residue method The following figure is the measurement interface of pesticide residue ...

Страница 48: ...t down Sample measure the sample solution then get the value A1 of sample solution Put the reference solution into test tube holder when the timer is to finish counting down the value of A2 of reference solution will be automatically read out Put the sample solution into test tube holder then the value of A2 and inhibition ratio will be obtained ...

Страница 49: ...can also customize dedicated measuring methods under quantitative measurement mode The ordinary procedure of water quality analysis select measuring methods select measuring module measuring sample save data check data print data Refer to instruction manual of water quality analysis for more information Figure 4 21 Choose the method the description characters of this method will turn into ...

Страница 50: ...struction Manual 48 deep color click start measuring at first it will remind you to choose appropriate measurement modules see fig 4 22 Figure 4 22 Click OK enter into the measurement interface shown in fig 4 23 ...

Страница 51: ...he measuring interface to measure after zeroing Start begin to measure Press Measure the system will carry out the real time measuring Save Save the measuring results Press Save a text box will pop up in which the user can input the name of the data If GPRS is on the data the relevant information will be uploaded in the mean time Timer start the predefined timer Exit back to the main page ...

Страница 52: ...gation bar to set the parameters The interface as Figure 4 24 will pop up which consist of parameter option page and instrument option page Parameter Setting Page Figure 4 24 The options can be set up are Coefficient Input the factors of the calibration curve different factors for different methods Concentration range display the upper and lower limits of concentration of this ...

Страница 53: ...anual 51 method Timers Count modify the number of timers and the time for them Significant figure number of significant digits displayed Instrument Setting Page Figure 4 25 Average times can be selected from 1 2 4 8 to 16 ...

Страница 54: ...ction Manual 52 Lamp Setting page Figure 4 26 Lamp on Lamp off set the status of the lamp Energy balance adjust the energy of tungsten lam After changing measurement assembly click this button to satisfy requirement ...

Страница 55: ... Figure 4 27 Sample Ent set the company of sample belongs to Sample Name set the name of measured sample Operator set the name of operator Enter the calibration standards page by clicking the button on the navigation bar then measure the standard sample ...

Страница 56: ...T3 T3M Instruction Manual 54 Figure 4 28 Add add a new standard sample you will first input the concentration of the standard sample as figure 4 29 shown ...

Страница 57: ...nd save Return return to the setting interface By shift between Standard and Curve can view the related data and fitting information See Figure 4 30 for the standard curve Note in case the first order curve is used at least two sets of standard samples should be measured in case quadratic curve is used at least three sets of standard samples should be measured ...

Страница 58: ...T3 T3M Instruction Manual 56 Figure 4 30 Curve Click the button in the navigation bar on the measurement interface can view the previous measuring results corresponding to the current method ...

Страница 59: ... all the data If all is selected the current option will be None which can clear the options Export insert the flash memory into the USB slot the user can export the data to it Upload upload the chosen data to the server 4 2 4 Quantitative Measurement The quantitative measurement is user defined the procedures for quantitative ...

Страница 60: ...ve measurement Figure 4 32 Quantitative The operations user can be done on the measuring main page are Zero zero before measurement According to prompt put in the blank solution return to the measuring interface to measure after zeroing Start begin to measure Press Measure the system will carry out the real time measuring Save Save the measuring results Press Save a text box will pop up in which ...

Страница 61: ... timer Exit back to the main page Dil Factor If the concentration exceeds the concentration limit it can be diluted before the test as a baseline for measurement Click the on the navigation bar to set the parameters The interface as Figure 4 33 will pop up which consist of parameter option page and instrument option page Parameter Setting Page Figure 4 33 Quantitative setting ...

Страница 62: ...ratic degree polynomial Concentration range display the upper and lower limits of concentration of this method Timers Count modify the number of timers and the time for them Significant figure number of significant digits displayed Unit Display or set the unit of the method ve Slope ve Slope display whether to choose fading measurement or not among which the values of absorbance slope and correlat...

Страница 63: ...T3 T3M Instruction Manual 61 Instrument Setting Page Figure 4 34 Average times can be selected from 1 2 4 8 to 16 ...

Страница 64: ...ction Manual 62 Lamp Setting Page Figure 4 35 Lamp on Lamp off set the status of the lamp Energy balance adjust the energy of tungsten lam After changing measurement assembly click this button to satisfy requirement ...

Страница 65: ...red sample Operator set the name of operator Save method use can save the current method as user defined method on measurement page Input the name in the pop up text box Calibration standards enter the calibration standards interface Enter the calibration standards page by clicking the button on the navigation bar then measure the standard sample ...

Страница 66: ...T3 T3M Instruction Manual 64 Figure 4 37 Add add a new standard sample you will first input the concentration of the standard sample ...

Страница 67: ...nd save Return return to the setting interface By shift between Standard and Curve can view the related data and fitting information See Figure 4 39 for the standard curve Note in case the first order curve is used at least two sets of standard samples should be measured in case quadratic curve is used at least three sets of standard samples should be measured ...

Страница 68: ...T3 T3M Instruction Manual 66 Figure 4 39 Curve Click the button in the navigation bar on the measurement interface can view the previous measuring results corresponding to the current method ...

Страница 69: ...lect all the data If all is selected the current option will be None which can clear the options Export insert the flash memory into the USB slot the user can export the data to it Upload upload the chosen data to the server Click the button on the navigation bar can view all the customer defined methods save in by the user ...

Страница 70: ...selected method Delete all clear the list of all the methods Note if the user does not select the method when the quantitative measurement is opened the default parameters will be those of previous measurement 4 2 5 Photometric Measurement Photometric Measurement means to read the measuring data at the certain wavelength That is to read the data at a fixed point the user can decide a ...

Страница 71: ... point and do the photometric measurement The process is set measuring parameters measure samples save data view data print data Figure 4 42 See Figure 4 42 for photometric measurement interface Press button into setting page see Figure 4 43 ...

Страница 72: ...of a wavelength point Coeff K the value displayed in the column K result is the result produced by point value measured multiplying this value ve Slope ve Slope display whether to choose fading measurement or not among which the values of absorbance slope and correlation coefficient are all negative COD low concentration Instrument Setting Page ...

Страница 73: ...tion Manual 71 Figure 4 44 Average times can be selected from 1 2 4 8 to 16 Integrating time set the integrating time the longer of integrating time the higher of energy Gain set the amplifier times Lamp Setting Page ...

Страница 74: ...on Manual 72 Figure 4 45 Lamp on Lamp off set the status of the lamp Energy balance adjust the energy of tungsten lam After changing measurement assembly click this button to satisfy requirement Sample information page ...

Страница 75: ...T3 T3M Instruction Manual 73 Figure 4 46 Set the information of sample Press button to enter the view page and view the saved photometric measurement results ...

Страница 76: ...g method in which the sampling is done continuously at a certain time interval and the sampling data is displayed in graphics This method is mainly applied to observe the trend of changes of the samples over time The process is set measuring parameters measure samples save data view data print data See Figure 4 48 for the measuring interface of kinetics scanning ...

Страница 77: ...T3 T3M Instruction Manual 75 Figure 4 48 See Figure 4 49 for setting interface ...

Страница 78: ...whether to choose fading measurement or not Instrument Setting Page Average times can be selected from 1 2 4 8 to 16 Integrating time set the integrating time the longer of integrating time the higher of energy Gain set the amplifier times under Es mode Lamp Setting Page Lamp on Lamp off set the status of the lamp Energy balance adjust the energy of tungsten lam After changing measurement assembly...

Страница 79: ...in spectral range at a certain wavelength interval and displaying the measured data in two dimensional graphics for further analysis and research The process is set measuring parameters measure samples save data view data print data See Figure 4 51 for the measuring interface of spectrum scanning ...

Страница 80: ...3 T3M Instruction Manual 78 Figure 4 51 See Figure 4 52 for setting interface New buttons added to the instrument setting page for the user to input the start wavelength end wavelength and scan Interval ...

Страница 81: ...T3 T3M Instruction Manual 79 ...

Страница 82: ...T3 T3M Instruction Manual 80 Figure 4 52 See Figure 4 53 for Browse interface ...

Страница 83: ...T3 T3M Instruction Manual 81 Figure 4 53 View the selected spectrum will be displayed on the measuring page see Figure 4 51 4 2 8 Setting The following is the interface of setting ...

Страница 84: ...T3 T3M Instruction Manual 82 Figure 4 54 Setting Functions of these buttons are as follows Date Time Set the system time by inputting the time ...

Страница 85: ...e operated if GLP is enabled Figure 4 56 GLP This instrument is equipped with GLP functions There are three parts of GLP functions user manager Log manager GLP settings User manager Different authorities for different user group different password for different users The user need input this password when power on the instrument and ...

Страница 86: ...T3 T3M Instruction Manual 84 unlock it when the GLP function is ON The default password for administrator is 888888 Figure 4 57 Here is the User manager interface ...

Страница 87: ...the information of this group Only allowed the administrator to carry on this operation Delete Group delete the chosen group Only allowed the administrator to carry on this operation Group Authority set the using authorities of chosen group select means the user group can do the corresponding operation Only allowed the administrator to carry on this operation ...

Страница 88: ...T3 T3M Instruction Manual 86 Figure 4 59 Group member list the user of this group choose the table of this list to edit user s information and password add new user delete user ...

Страница 89: ...T3 T3M Instruction Manual 87 Figure 4 60 Log manager All the operation will be record into the log Click Log to view ...

Страница 90: ...ormation GLP Setting If the user belongs to the administrator group Setting button will be visible which can be used to control the GLP function ON and OFF and set the owner organization of this instrument While which is invisible to the user not belong to the administrator group ...

Страница 91: ...T3 T3M Instruction Manual 89 Figure 4 62 Volume Volume setting is used to adjust the volume of the system ...

Страница 92: ...GPRS Figure 4 64 GPRS Location Make sure SIM card is inserted and click GPRS to locate by GPRS It will remind you base station code and signal quality after location is completed GPS Location Make sure GPS vehicle mounted external antenna is well connected click GPS then it starts GPS location Longitude and latitude will be displayed after location is completed ...

Страница 93: ...on Make sure SIM card is firmly inserted be aware that notched direction heads down Power off when installing or replacing the card Make sure the antenna is firmly connected and place the instrument in an area with good signal when using GPS function avoid interruption and shielding Put the antenna of the GPS into the GPS holder and keep the black side upward If the unit is used indoor put it clos...

Страница 94: ... address automatically Figure 4 66 Notice Likewise make sure SIM card is recharged when using GPRS Make sure SIM card is firmly inserted be aware that notched direction heads down Switch off the power supply when installing or replacing the card Printer Printer Setup screen will list the printer that once connected to the instrument A printer needs to be selected as the default printer If the prin...

Страница 95: ...ails to response the clicks correctly the user can enter into this module and click the centers of the small crosses to calibrate the screen Debug Mode Debug Mode is used for the after sale service personnel to maintain the instrument Input the password will enter the maintenance mode the password is not open to the customer ...

Страница 96: ...T3 T3M Instruction Manual 94 PC Mode Only on PC mode the T3 data viewer can download data from T3 and update Click PC Mode it will ask you Figure 4 68 Click OK it will show you ...

Страница 97: ...T3 T3M Instruction Manual 95 Figure 4 69 Reset Reset the instrument ...

Страница 98: ...T3 T3M Instruction Manual 96 Figure 4 70 About Get the Serial Number Software name Software version manufacture information and so on from here ...

Страница 99: ...T3 T3M Instruction Manual 97 Figure 4 71 4 3 Video Method videos of food analysis and water quality analysis can be viewed under this module The interface of Method video is shown as follows ...

Страница 100: ...ion Manual 98 Figure 4 72 Play video Pause Video back Video forward Stop Full screen Volume up Volume down Quit the interface of method video The list of video files can be viewed after pressing the button Browse the ...

Страница 101: ...T3 T3M Instruction Manual 99 format is wmv Select relevant video files and see the files after clicking View Figure 4 73 ...

Страница 102: ...it T3 data viewer can export the measured result or the spectrum to text document txt or csv T3 data viewer can print the measured result or the spectrum by the printer connected with PC T3 data viewer can be used to update the instrument 5 1 Software installation T3 data viewer must be run on the PC with following software Microsoft net Framework 2 0 Windows Mobile Device center provides the devi...

Страница 103: ...data viewer software CD disk into CD driver of PC and double click ViewerSetup exe the following figure will show Figure 5 1 The software will ask you to install the Microsoft net Framework 2 0 if without it Continue to install the T3 Data Viewer software after installing Microsoft NET ...

Страница 104: ...T3 T3M Instruction Manual 102 Framework 2 0 Press Next it will show you Figure 5 2 Click Browse to choose the installation directory press Next it will show you ...

Страница 105: ...T3 T3M Instruction Manual 103 Figure 5 3 Press Next to continue it will show the following figure after the installation is finished ...

Страница 106: ... 5 1 2 Installation of Microsoft Net Framework 2 0 Find the Microsoft NET Framework 2 0 exe installation program from the CD disk and install as the prompt 5 1 3 Installation of Windows Mobile Device Center On Windows 2000 XP system synchronization between the main unit and PC is ...

Страница 107: ...he disk 5 2 Software operation 5 2 1 Start Start the T3 data viewer software by the following solution Double click the T3 data viewer v1 0 icon from the desktop to start Start Program T3 data viewer v1 0 Double click the T3 data viewer exe from the installed file There are four parts for the software interface menu toolbar document list data browsing page There are six functions of the data brows...

Страница 108: ... 2 Download data Open the download window by choosing download data from file or clicking from toolbar Before download the data make sure the connection between the main unit and communication cable is correct and the synchronization is achieved ...

Страница 109: ... connecting with PC Press Import index button to download data index from instrument Press Import All to download all the data to default path when the download of data index is finished Or choose some data and press Import chosen items to download Save the data file as default name or other name 5 2 3 File processing On the left of the main interface is file list The software will list all the da...

Страница 110: ... Measurement data Measurement data Figure 5 7 Double click the measurement data or choose the data and click button to open it It will show you the saved path simple description and create time if the cursor hovering on the File name By choosing File Open index to add the data into the list if the data are saved in the flash memory or the other path of the PC See the following picture ...

Страница 111: ... the same file and the storage file can t be renamed or the index cannot find the corresponding measurement data 5 2 4 Browse Spectrum Kinetics data The page structure for Spectrum and Kinetics are the same which can display spectrum measurement parameters and peak picking results Spectrum can be operated and analysis by the T3 data viewer software Figure ...

Страница 112: ...r Full View Display spectrum on full screen Move Moving the spectrum by holding the cursor Ruler Distance measuring positioning by dragging the acute angle of the triangle Crosshair Read the point data by moving the plus cursor on spectrum Read Value The horizontal line and vertical line will show on the spectrum the cross point of horizontal line and vertical line will move to the peak or valley ...

Страница 113: ...ck Show the peak value on spectrum and show the result of peak picking on the list Adjust the peak picking result by changing Peak Threshold Valley Threshold Set up the display of peak picking result on the list by Show peak Show valley which is shown as figure 5 10 Zoom in Zoom in spectrum automatically Zoom out Zoom out spectrum automatically Figure 5 10 ...

Страница 114: ...d measurement result on Quantitative page Also can be printed and saved When open several measurement data with the same calibration method new lines will be add to the measurement result list When open with different calibration method the measurement result list will be displayed from the first line When open multi files stop browsing or printing by choosing Edit Delete current Row s File Data T...

Страница 115: ...T3 T3M Instruction Manual 113 Figure 5 11 5 2 6 Browse photometric measurement result Display measurement result and parameters on the Photometry page which is shown as the following figure ...

Страница 116: ... Delete current Row s File Data when browsing data this operation will not delete data 5 2 7 Export data Open the export wizard by choosing File Data export or clicking on toolbar If current page is peak picking status choose the export type first which is shown as the following figure ...

Страница 117: ...T3 T3M Instruction Manual 115 Figure 5 13 Press Next to set the file format and path which is shown as the following figure ...

Страница 118: ... be opened by WordPad program of Windows And the text file also can be opened by Microsoft Excel 5 2 8 Print Set up print parameters by choosing File Print Setup which is including page setup which including content setting and page setting For the content setting the report setting can be edit such as the title author and sample information can be edited See the following figure ...

Страница 119: ...T3 T3M Instruction Manual 117 Figure 5 15 Figure 5 16 is page setting including page setting and printer setting ...

Страница 120: ...T3 T3M Instruction Manual 118 Figure 5 16 Print by choosing File Print or clicking of toolbar ...

Страница 121: ...trument is successfully connected with PC and under PC mode See the picture below Figure 5 17 Current version The software version of the instrument will be displayed after the instrument is synchronous with the PC Updated version The software version needed to be downloaded will be displayed after the instrument is synchronous with the PC ...

Страница 122: ...e recovered to previous one Link to device Link PC and the instrument error warning will be displayed if synchronization fails Click Browse select the update program needed Then click Update to start Figure 5 18 After the update is completed the interface shown below will appear Restart the instrument and the new program is launched ...

Страница 123: ...T3 T3M Instruction Manual 121 Figure 5 29 ...

Страница 124: ... surface of the probe maybe has some filth Remove the tip of the probe and clean it with a alcoholic cotton tack It should avoid dust covering the surface of the reflecting mirror after the fiber probe is used If the operation is not done for a long time please turn off the power supply of the lamp to save the battery energy After the charging is finished the indicator is off please turn off the p...

Страница 125: ...llows 1 Open the battery cover on the back of the main unit see fig 6 1 get out the batteries if the batteries are stuck make the batteries downward and shake it then the batteries can be taken out Figure 6 1 2 Pull out the battery lead attention Curl the lead and slip it inside the enclosure when installing the lead into the batteries Drag out the lead carefully with a screwdriver Finally drag ou...

Страница 126: ...e power cable and put the rest of the cable into the main unit then put the batteries inside the holder cover the main unit Tight the 4 fixed screws 6 3 Replacement of fiber probe and reflection mirror Replacement for fiber detector if the fiber probe is broken or destroyed please contact the manufacturer for replacement The trouble phenomenon is that the energy scanning reading is close to zero w...

Страница 127: ...that the energy reading at 560nm is lower than 10 when the gain is 1 and integrating time is 0 005s in energy scanning Please contact the manufacturer for replacement The replacement methods are as follows The valid time for the fiber detector top is 2 years When the energy is lower please contact the manufacturer for replacement Figure 6 4 Replacement for fiber detector top ...

Страница 128: ...d power switch broken 3 Very low energy and bad baseline replace with a new tungsten lamp 4 Check if there is something block the light in the cell holder 3 The noise of the instrument is too large 1 Energy balance blank correction 2 Check if the sample is turbidity and if there is besmirch in the sample chamber for the fiber 3 Check if the power for the battery is enough 4 Check if the power supp...

Страница 129: ...tware 5 Baseline flatness is over the limitation 1 Do the baseline correction again 2 Ensure that the cell holder is fixed 3 Check if the power for the battery is enough 4 Check if the energy is too low to do the energy balance 6 The drift of the instrument is big 1 Check if the power for the battery is enough 2 Repeat zeroing after warming up 7 The wavelength of the instrument is not precise Retu...

Страница 130: ...arger is correct 3 Check if the connector of charger is correct 4 Replace the battery 11 Cannot enter into main interface Restart 12 Export to flash memory error 1 Check the flash memory 2 Check the connection of flash memory is correct or not 13 The synchronous between instrument and PC error cannot export the data 1 Check whether the USB cable is normal 2 Make sure the instrument is under PC mod...

Страница 131: ...clean and not damaged 3 Check whether the SIM card is correctly inserted into the slot 4 Turn off the main unit and insert the SIM card again restart the instrument 15 GPS location unavailable 1 Check whether the external antenna of the GPS is damaged 2 Check whether the antenna of the GPS is firmly installed 3 Check whether there is any block or electromagnetic interruption around make sure imple...

Страница 132: ...sh disk 17 Cannot print 1 Check whether the selection of printer setting in system setting is correct 2 Make sure the setting of the printer is correct 18 Others When it goes wrong please check the troubles step by step If the troubles can t be settled please contact your local dealers Chapter 8 Instrument configuration Note The following drawings for accessories case are only for ...

Страница 133: ...configuration is based on the sales contract Figure 8 1 Spare parts list Pipette 5ml Pipette 1ml Wash bottle Cell holder Test tube Main unit Cuvettes Test tube φ16mm Test tube φ25mm Mini triangle stand GPS module GPS antenna USB cable Charger pH meter ...

Страница 134: ...T3 T3M Instruction Manual 132 Test tube φ16mm 9 Test tube φ25mm 2 Glass cuvettes 10mm path length 1 Glass cuvettes 20mm path length 1 Glass cuvettes 50mm path length 1 Test tube 1 ...

Страница 135: ...truction Manual 133 Persee Analytics Inc Address 7270 Popham Place Solon OH44139 United States Contact Sean Cao Title Sales and Marketing Director E mail jia cao pgeneral com Tel 440 591 9268 Web www perseena com ...