DATI TECNICI
DATI TECNICI
TECHNICAL DATA
Supply voltage:
Type of action, disconnect and device:
Type of output:
Output connection (load):
Inputs for “Reduction” control, remote:
Maximum wire section at terminals:
Insulation type:
Protection degree:
Pollution:
Operating temperature limits:
Storage temperature limits:
Temperature adjustment range:
Settable max. temperature limit:
Reduction temperature:
Precision of reading of the temperature:
Operation:
Differential operation:
Thermal gradient:
ERP Energy classification:
Reference standard for CE mark:
230 V~ 50 ÷ 60 Hz
1/ B / Electronic
relay with changeover contact NO / COM / NC
voltage free - max 8(2)A / 250 V
~
2 or 3 conductors
for voltage free contact (models where provided for)
supply voltage = 2,5 mm
2
relay contact
= 2,5 mm
2
reduction remote = 1,5 mm
2
(models where provided for)
Class II
I 30
P
Normal
0 °C ÷ +50 °C
-10 °C ÷ +65 °C
+5 °C ÷ +30 °C
16,18, 20, 22, 24 °C (settable with range disc)
- 4 °C from temperature setpoint
± 1 °C
ON/OFF with differential
D
t = 0,4 °C (fixed)
1 °K/15 min
ErP: Class I; 1% Reg. EU 811/2013
LVD EN60730-2-9
EMC EN60730-2-9
SAFETY PRECAUTIONS
Before starting any operations on the device, disconnect the 230V~ mains power supply
Read this manual carefully before using the product as it provides important guidelines regarding safety, installation and use.
The manual must be preserved with care for future reference. The manufacturer reserves the right to introduce any technical
and/or constructive changes deemed necessary, with no prior notice.