Supply voltage:
Solenoid valve control relay:
Relay contact capacity (max):
Protection category:
Insulation:
Buzzer:
Environment of application:
Operating temperature:
Operating humidity:
Types of gas detected:
Alarm level:
Sensor warm-up time at power-on:
BUS connections
Max BUS configuration:
Max connection length:
Reference standards for CE marking:
TECHNICAL CHARACTERISTICS
230 V~ 50 ÷ 60 Hz
1 changeover contact, zero potential
8 (2) A / 250 V ~
6 (2) A / 250 V ~
semi flush-mounted
IP 42
IP 40
semi flush-mounted
Class II
85 dB at 1 metre
Household or similar
-10 °C ÷ +40 °C
90% RH (maximum)
Natural gas
- for Natural gas model
LPG
- for LPG model
10% LEL - ( ower xplosive imit)
L
E
L
1 minute
1 main unit with 14 remote units
1 km (with 2 wires of 1.5 mm section)
2
LVD EN 50194
CEI 216-8
semi flush-mounted
EMC EN 50270
PRINCIPAL SIGNALS AND CONTROLS
PERFORMANCE FEATURES
Performance (both models):
- Alarm memory
- Clear alarm memory
- Prepared for BUS connections
Green Led - Mains active
Yellow Led - Appliance fault
Red Led 1 - Alarm status
RESET
TEST
ON
Red Led 2 - Low presence of gas
Red Led 3 - Very low presence of gas
RESET button
ON - TEST selector
Other luminous signals:
- Alarm memory
- Sensor warm up time
- Appliance and/or BUS fault
- Replacement warning
(*)
more than 5 years
(* - with audible signal)
Principal controls
"Reset" button:
- Clear alarm memory
- Appliance replacement warning signal overriding
- System configuration with BUS connection
Slide selector:
- Test installation
- System configuration with BUS connection
(Fig. 1)
- Sensor warm-up time
14
EN
LED indicators
and buzzers
intermittent
Off
LED
BUZZER
permanently
alight