Perlick BR48 Скачать руководство пользователя страница 8

Form no. Z2278

rev. 05.06.10

8300 West good hope road  •  Milwaukee, Wi 53223  •  Phone 414-353-7060  •  Fax 414-353-7069

toll Free 800-558-5592  •  e-Mail: [email protected]  •  www.Perlick.com

Perlick is committed to continuous improvement. therefore, we reserve the right to change specifications without prior notice.

[2] dooR

MULLION HEATER

MULLION HEATER

MULLION HEATER

RED

BLACK

BLACK

BLACK

RED

BLACK

WHITE

WHITE

BLACK

BLACK

WHITE

WHITE

GREEN

BLACK

WHITE

GREEN

EVAPORATOR FAN

EVAPORATOR FAN

NOTE:

FIELD WIRING FROM CABINET 

JUNCTION BOX TO CONDENSING  

UNIT MUST COMPLY WITH ALL 

LOCAL AND NATIONAL ELECTRICAL 

CODES.

CABINET

JUNCTION BOX

CONDENSING UNIT

EVAPORATOR

HOUSING

GROUND WIRE

JUNCTION BOX

PRESSURE SWITCH

FIELD INSTALLED

POWER CONNECTION

THESE WIRES CAPPED IN

SINGLE CABINET

INSTALLATIONS

LIGHT

LIGHT

LIGHT

LIGHT

WHITE

WHITE

LIGHT SWITCH

[3] dooR

[4] dooR

[2] dooR

MULLION HEATER

MULLION HEATER

MULLION HEATER

RED

BLACK

BLACK

BLACK

POWER CONNECTION

JUNCTION BOX

CONDENSING UNIT

WHITE

RED

GREEN

BLACK

WHITE

GREEN

BLACK

THERMOSTAT

BLACK

WHITE

WHITE

EVAPORATOR FAN

EVAPORATOR FAN

LIGHT

LIGHT

LIGHT

LIGHT

WHITE

WHITE

LIGHT SWITCH

[3] dooR

[4] dooR

Wiring Diagram – 

Custom back bar Cabinets

bR Series Remote
2, 3 and 4 door

bS Series Self-Contained

2, 3 and 4 door

8

Содержание BR48

Страница 1: ...l then Service You will see the link to Warranty Registration Form You must complete and submit this form or the installation date will revert back to the ship Date This manual has been prepared to as...

Страница 2: ...ware Door handles Choice of full length stainless steel classic 6 black vinyl wrapped pull or top mounted stainless steel pull tab Lock finish chrome REFRIGERATION R 134a capillary tube type Aluminum...

Страница 3: ...Aluminum fin and copper tube evaporator epoxy coated coil Factory installed expansion valve Choice of R22 or R404A Copper tube connection stubbed out left side of evaporator assembly Suction line acc...

Страница 4: ...ing Carefully inspect cabinet for hidden damage If damage is discovered file your claim immediately with the transportation company Perlick is not responsible for damage in transit Installing Casters...

Страница 5: ...al strength commercial cleaner can be used to clean the outside of painted cabinets Cleaning the Condenser Use a long handled stiff brush to clean the dirt from the front surface of the condenser Keep...

Страница 6: ...65538 65539 65540 Wire harness mullion heater 65571 65572 65573 Light bulb 63821 63821 63821 Light bulb guard 65525 65525 65525 Light socket 63484 63484 63484 Light switch 65535 65535 65535 Lock 63762...

Страница 7: ...assemble lock rail from STEP 3 Operations to Perform on Door STEP 11 Remove bottom door hinge bracket from door assem bly and remove door hinge bushing from bracket Re assemble door hinge bracket to p...

Страница 8: ...TO CONDENSING UNIT MUST COMPLY WITH ALL LOCAL AND NATIONAL ELECTRICAL CODES CABINET JUNCTION BOX CONDENSING UNIT EVAPORATOR HOUSING GROUND WIRE JUNCTION BOX PRESSURE SWITCH FIELD INSTALLED POWER CONNE...

Отзывы: