reversing Door hinge

Form no. Z2278

rev. 05.06.10

Tools Required

  ■ 

 #3 Phillips Screwdriver.

  ■ 

1

/

16

” allen Wrench.

  ■ 

Flathead Screwdriver

Right Hinged door

(as shipped from factory)

Operations to Perform on Cabinet

STEP 1:

 

remove bottom hinge pin from 
assembly.

STEP 2:

 

Carefully lift and tilt out door 
assembly from the unit and 
set aside.

STEP 3:

 

remove lock rail from 
cabinet, requires removal of 
four screws.

STEP 4:

 

remove top hinge pin. 
remove top and bottom 
hinge brackets from the unit.

STEP 5:

 

remove hinge bushing from 
bottom hinge bracket and 
assemble to top hinge bracket.

STEP 6:

 

taking care not to scratch the 
surface, remove hole plugs from 
the left hinge holes.

STEP 7:

 

insert hole plugs into vacant right 
hinge holes.

STEP 8:

 

re-assemble hinge brackets to unit. bottom right bracket 
is assembled as the top left bracket. top right bracket is 
assembled as the bottom left bracket.

STEP 9:

 

re-insert top hinge pin.

STEP 10:

 

re-assemble lock rail from 
SteP #3

Operations to Perform on door

STEP 11:

 

remove bottom 
door hinge bracket 
from door assem-
bly and remove 
door hinge bushing 
from bracket. 
re-assemble door 
hinge bracket to 
previous position, 
without bushing.

STEP 12:

 

remove top door 
hinge bracket from 
door assembly and 
assemble door 
hinge bushing from 
SteP 11 to bracket. re-assemble door hinge bracket to 
previous position with bushing attached.

STEP 13:

 

door with full length SS handle: 

 

there is no need to remove door handle. it will be  

 

positioned correctly when door is reversed.

door with SS pull tab or handle with wrap-  
around bracket: 

 

 

remove the two screws mounting the handle and  

 

reposition to appropriate location on the opposite  

 

side of the door.

STEP 14:

 

remove lock retainer and install on opposite end of door.

STEP 15:

 

What was the door top is now the door bottom. Carefully 
lift the door onto the hinge brackets of the cabinet. the 
two hinge bushings should meet. reinsert the bottom 
hinge pin to complete the door switching operation.

Step #12

Step #11

Step #13

Step #14

Step #6

Step #7

Remove 

these screws

Top Hinge bracket

Bottom Hinge Bracket

Top Hinge Bracket

Bottom Hinge Bracket

Hinge bushing

65305-1

65189

65609-2

C31409-1

Not 

Reversible

Handle Styles

Содержание BR48

Страница 1: ...l then Service You will see the link to Warranty Registration Form You must complete and submit this form or the installation date will revert back to the ship Date This manual has been prepared to as...

Страница 2: ...ware Door handles Choice of full length stainless steel classic 6 black vinyl wrapped pull or top mounted stainless steel pull tab Lock finish chrome REFRIGERATION R 134a capillary tube type Aluminum...

Страница 3: ...Aluminum fin and copper tube evaporator epoxy coated coil Factory installed expansion valve Choice of R22 or R404A Copper tube connection stubbed out left side of evaporator assembly Suction line acc...

Страница 4: ...ing Carefully inspect cabinet for hidden damage If damage is discovered file your claim immediately with the transportation company Perlick is not responsible for damage in transit Installing Casters...

Страница 5: ...al strength commercial cleaner can be used to clean the outside of painted cabinets Cleaning the Condenser Use a long handled stiff brush to clean the dirt from the front surface of the condenser Keep...

Страница 6: ...65538 65539 65540 Wire harness mullion heater 65571 65572 65573 Light bulb 63821 63821 63821 Light bulb guard 65525 65525 65525 Light socket 63484 63484 63484 Light switch 65535 65535 65535 Lock 63762...

Страница 7: ...assemble lock rail from STEP 3 Operations to Perform on Door STEP 11 Remove bottom door hinge bracket from door assem bly and remove door hinge bushing from bracket Re assemble door hinge bracket to p...

Страница 8: ...TO CONDENSING UNIT MUST COMPLY WITH ALL LOCAL AND NATIONAL ELECTRICAL CODES CABINET JUNCTION BOX CONDENSING UNIT EVAPORATOR HOUSING GROUND WIRE JUNCTION BOX PRESSURE SWITCH FIELD INSTALLED POWER CONNE...

Отзывы: