DIP Switch Settings
The DIP switches are accessible through the opening in the side
of the enclosure.
Note: Switch changes made when the product is powered up take
effect immediately and will result in a link reset on both ports.
Operating Mode (Switch 1)
Switch Position
Mode
Up (default)
Data
Down
Test
Data: In Data mode, data will flow between the fiber connection
and the copper port.
Test: Test Mode is used to run diagnostics, enable loopback and
for running the Built In Link Test.
Note: The Operation Mode (Switch 1) affects the function of DIP
Switch 2 and 3 when in Test Mode.
Link Mode (Switch 2 – Data Mode)
Switch Position
Mode
Up (default)
Smart Link Pass-Through Mode
Down
Standard Mode
Smart Link Pass-Through: In this mode, the link state on one
port connection is directly reflected through the media converter to
the other port connection. If the link is lost on one of the
connections, then the other link will be brought down by the media
converter.
Standard Mode: In this mode, the links can be brought up and
down independently of each other. A loss of link on either
connection can occur without affecting the other fiber connection