Resetting the Switch
The Reset/Fast Setup button is located near the bottom of the switch. A small tool such as
a paper clip is needed to access the recessed button.
Soft Reset
To reset/restart the switch you can perform a soft reset. Press and immediately release the
reset button to perform a soft reset.
Hard Reset
Hard Reset performs a power-off of the switch without requiring a disconnection of
power. Once powered off, the switch can be powered back on by pressing the reset switch
again or by disconnecting power at source and re-applying.
Press and hold the reset button for at least 8 seconds. The switch will perform a complete
power down and stay in the powered off state. Press the reset button again to power the
switch on.
Reset to Factory Default Configuration
The switch can be reset to the Factory default configuration. When this is done, all config
-
uration, user IDs, passwords and security certificates are deleted. The start-up and backup
software are unaffected. Follow this procedure:
LED
Behavior
PWR
The PWR LED will remain solid yellow
during the boot process. Once the system
software has been loaded the PWR LED will
reflect the status of the power inputs.
LED
Behavior
ALL
All LEDs will be off after 8 seconds.
Содержание IDS-509F
Страница 29: ...Appendix B Sample Labels 27 IDS 509F Hardware Installation Guide Appendix B Sample Labels ...
Страница 30: ...Appendix C Mechanical Drawings 28 IDS 509F Hardware Installation Guide Appendix C Mechanical Drawings ...
Страница 31: ...Appendix C Mechanical Drawings 29 IDS 509F Hardware Installation Guide ...
Страница 32: ...Appendix C Mechanical Drawings 30 IDS 509F Hardware Installation Guide ...