22
IDS-509CPP Hardware Installation Guide
Appendix A - Technical Specifications
This appendix provides the technical specification for the IDS-509CPP(-XT) switches.
Technical Specifications
Power
Power Connector
•
4-Pin Removable Terminal Block
•
Grounding screw on metal chassis
•
Dual Power Input
Dual Power Input
•
54 VDC nominal 50-57 VDC (Poe+ IEEE 802.3at
type 2, 5.5A Max
•
48 VDC nominal 44-57 VDC (PoE 802.3af or
IEEE 802.3at type 1), 5.5A Max
Alarm Relay
•
NO (Normally Open), NC (Normally Closed
contacts
•
1.0A @ 24VDC or 0.3A @ 48VDC
•
Requires Class 2/LPS or SELV circuit with Fuse
protection
Digital Input: IN1
•
Connects to Dry Contact Circuit
•
Provides: 12V, 36mA
•
On: > 2.1mA (< 4K Ohms)
•
Off: < 1.2mA (>9K Ohms)
Digital Input: IN2
•
Connect to Wet Contact Circuit (requires external
power)
•
Input Voltage Rating: -36 to +36 VDC
•
Input Impedance: 4K Ohms
•
On: >10VDC
•
Off: <5VDC
Rated Cable Temperatures
IDS-509CPP
IDS-509CPP-XT
>98° C
>106° C
Overload Current Protection
Fuse
Reverse polarity protection
Yes