13
IDS-509CPP Hardware Installation Guide
Warning
: If this equipment is used in a manner not specified by the manufacturer, the protection pro-
vided by the equipment may be impaired.
Warning
:
In case of malfunction or damage, no attempts at repair should be made. Do not dismantle
the product. All repairs need to be made by a qualified Perle representative.
Warning
:
Explosion hazard. Do not remove or replace any ports, connectors, memory cards, lamps,
fuses plug-in modules (as applicable) or operate unless power has been disconnected or the area is free
of ignitable concentrations.
Warning
:
Explosion hazard. Do not disconnect while the circuit is live or unless the area is free of ignit-
able concentrations.
Warning
:
Transient protection shall be provided that is set at a level not exceeding 140% of the peak
rated voltage at the supply terminals to the equipment.
Terminal Block Connectors
Grounding the IDS switch
If your installation requires additional grounding, follow this procedure.
Grounding the chassis requires the following items:
•
One grounding lug (not provided)
•
One 12AWG wire (not provided)
Follow the manufacturers instructions for attaching the ground wire to the grounding lug.
Attach the grounding lug to the chassis and secure with the grounding screw provided.
Connecting Power to the IDS Switch
The IDS switch has two power inputs that can be connected simultaneously to provide
redundant power. If one power source fails the other source acts as a backup, and powers
the switch
Wiring with suitable temperature ratings must be used. Refer to specification section for
details. Use copper wire only if the terminal is only for connection to copper wire.
1. Ensure the power source is off prior to connection
2. Strip both (12-20AWG) wires 7-8 mm(5/16th)
3. Loosen the terminal block screws and connect positive (+) / negative (-) wires into the
+/- terminals
4. Tighten terminal screws (0.5Nm torque). Ensure the wires are securely fastened.
5. Re-insert the Terminal Block connector if removed, Turn on power source. Check
LED indicators in the guide for power status
6. Connect P2 (power source 2, beginning at Step 1)
7. Ensure that there is one individual conductor for each clamping point.
See