background image

Installation     12

IDS-305F Hardware Installation Guide

3

Click the Hardware tab and choose Device Manager, Expand the Ports(COM & LPT) section. This will 
expand the drop down to show the number of com ports on your system. Connect the cable to one 
of these ports (probably com1 or com2).

4

Start an terminal-emulation program (such as Putty or SecureCRT ) on the COM port where you have 
connected the  cable PC.

5

Configure this COM port within the terminal emulation program with the following parameters:
• 9600 baud
• 8 data bits
• 1 stop bit
• No  parity
• None (flow control)

6

Connect power to the switch as described in Connecting Power to the IDS Switch. 

7

The PC will display the bootloader sequence.

8

When the booting (see Booting, Resetting the Switch) of the IDS is completed, press Enter to 
display the setup prompt.

Warning

If you connect or disconnect the console cable with the power applied to the switch or any 

device on the network, an electrical arc can occur. This could cause an explosion when installed in a haz-
ardous location. Ensure the power is removed from all devices prior to making the cable connection.

Connecting Destination Ports

Data Port Connections

By default all of the 10/100/1000 ports will automatically set themselves up to match the speeds of all 
attached devices. If auto negotiation is not supported by one or more attached devices, the ports can 
be configured to operate at fixed speeds and duplex settings.

Warnin

g: 

In hazardous location installations, failure to remove the power from the source prior when 

completing the wiring connections to the Ethernet ports could cause an electrical arc resulting in a pos-
sible explosion.

To connect to 10Base-T, 100Base-TX or 1000Base-T follow these steps:

1

When connecting to devices, workstations, servers or routers connect a straight through Ethernet 
cable to a 10/100/1000 RJ45 connector on the front of the IDS switch. Gigabit Ethernet requires 
CAT5 or better.

2

Once the device is connected and link is established the link LEDs will turn on. These LEDs will 
indicate whether you have a 10,100 or 1000 Mb/s link to the switch. See. (LED Indicators) for more 
details.

Note: 

It may take a few seconds for the device to become active. By default the IDS switch will have 

Rapid Spanning Tree (RSTP) protocol enabled. This protocol will first check the network for any cabling 
loops prior to bringing the port up, in order to prevent network disruptions.

To connect to the 100Base-X Fiber devices:

1

Connect a fiber with the appropriate connector and fiber type for the specific IDS model. Ensure 
that the device being connected to matches the fiber characteristics of the switch.

2

Once the fiber is connected and a link is established the LED (5) will display link and activity. 

Содержание 07012410

Страница 1: ...IDS 305F Hardware Installation Guide Managed Industrial Ethernet Switches Updated September 2016 Revision 1 00 Document Part 5500374 10 www perle com...

Страница 2: ...rence when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this hardware gui...

Страница 3: ...Connecting the Console Port 11 Connecting Destination Ports 12 Resetting the Switch 13 Booting the Switch 14 Fast Setup Mode 14 Password Recovery 14 Configuring the IDS Switch 15 Appendix A Technical...

Страница 4: ...ts IDS switch with attached DIN rail mounting bracket Quick Start Guide Document Conventions This document contains the following conventions Most text is presented in the typeface used in this paragr...

Страница 5: ...For more details and for the most up to date list of models please refer to the product pages at www perle com Note xxxxxx denotes the specific type of fiber port installed Refer to the Perle Website...

Страница 6: ...4 IDS 305F Hardware Installation Guide Switch Model View IDS 305F Note Fiber Port may appear different depending on the type of fiber port installed...

Страница 7: ...after power on System booting Green solid System ready operating normally Green blinking slowly Fast Setup Mode activated port available Green blinking fast Fast Setup Mode activated no port available...

Страница 8: ...ter Active redundant port blocked Coupling Link enabled Green flashing Ring Master unable to establish a ring due to missing link on one of the Ring ports Yellow solid Ring Master Active redundant por...

Страница 9: ...provide a built in fiber module that provides fiber connectivity at 100 Mb s These fiber ports are available on the switches in a variety of distances wavelengths and connector types Consult the full...

Страница 10: ...hernet Port Status Indicators Port Link Speed Green and Yellow LEDs State Description Green 1000 Mbps Green Yellow 100 Mbps Yellow 10 Mbps On solid Port Link Random blinking Port Link and Activity Slo...

Страница 11: ...g or office environment the device must be operated exclusively in switch cabinets with fire protection characteristics in accordance with EN 60950 1 Warning The working voltage inputs are designed fo...

Страница 12: ...arning In case of malfunction or damage no attempts at repair should be made Do not dismantle the product All repairs need to be made by a qualified Perle representative Warning Explosion hazard Do no...

Страница 13: ...e IDS switch has a Normally Closed NC relay with terminals located on the top panel of the unit The IDS switch can be connected to an external powered device such as a siren or light for visual or aud...

Страница 14: ...attached devices If auto negotiation is not supported by one or more attached devices the ports can be configured to operate at fixed speeds and duplex settings Warning In hazardous location installat...

Страница 15: ...ill perform a complete power down and stay in the powered off state Press the reset button to power the switch on Reset to Factory Default Configuration The IDS 305F can be reset to the Factory defaul...

Страница 16: ...Start Guide that came with your IDS switch on how to connect to your switch for the first time Password Recovery When the switch is not in factory default the Fast Setup Mode sequence will activate P...

Страница 17: ...re information Web Device Manager The Perle Web Device Manager is an embedded Web based application that provides an easy to use browser interface for managing the switch This interface provides the a...

Страница 18: ...connector Fiber 100Base X Fixed Fiber SC ST varies by model Console RJ 45 connector LED Indicators PWR Power Inputs SYS System Status ALR Alarm BC For Future Use RM For Future Use 5 Fiber Port Link A...

Страница 19: ...L 60950 1 EN 60950 EN IEC 60950 Industrial Safety UL 61010 1 UL 61010 2 201 EN 61010 1 EN 61010 2 201 EMI EMC FCC 47 Part 15 Class A CISPR22 2008 EN55022 2010 Class A CISPR 24 2010 EN55024 2010 Standa...

Страница 20: ...18 IDS 305F Hardware Installation Guide Appendix B Labels IDS 305F IDS 305F XT...

Страница 21: ...19 IDS 305F Hardware Installation Guide Appendix C Mechanical Drawings 5 port RJ 45...

Страница 22: ...the DIN rail cliponto the bottom of the DIN rail See diagram below Removing the IDS from the DIN Rail 1 The DIN rail attachment clip has a slot at the bottom of the latch that is visible beneath the...

Страница 23: ...from the wall to allow room for sliding the wall mount panel between the wall and the screws 5 Once the screws are fixed to the wall insert the four screw heads through the large parts of the keyhole...

Страница 24: ...inches on all sides of the IDS switch to provide proper airflowthrough the unit Do not use solvents or cleaning agents on this unit Keep vent holes clear of debris If case gets dirty wipe with a dry...

Страница 25: ...evices These Ethernet ports will automatically adjust depending on the type of Ethernet cable used straight through or cross over and the type of device NIC type or HUB Switch type con nected to the p...

Страница 26: ...e Single mode 9 125 micron fiber cable Simplex BIDI single strand SC or ST connector Multimode 50 125 or 62 5 125 micron fiber cable Single mode 9 125 micron fiber cable Connect the fiber cable to Por...

Отзывы: