Table 19
Oil Change Interval for 1706J and 1706EA Industrial Engines
Multigrade Oil Type
Operating Conditions
Normal
Severe Service Application
Perkins DEO
or Perkins DEO-ULS
Preferred
500 hr
250 hr
Oil meeting the requirements of the Perkins
ECF-3 Specification or the API CK-4
classification
8 minimum TBN
Preferred
500 hr
250 hr
Oil meeting the requirements of the ACEA C9/
E6 Specification
TBN below 10.4
500 hr
250 hr
(1)
The standard oil change interval in this engine is 500 hours, if the operating conditions and recommended oil types that are listed in this table
are met. Ifthe type of oil, the quality of the oil and the operating conditions fails to meet certain standards, the oil change intervals must be de-
creased to 250 hours.
Drain the Engine Lubricating Oil
Note:
Ensure that the vessel that will be used is large
enough to collect the waste oil.
After the engine has been run at the normal
operating temperature, stop the engine. Attach a
“
DO
NOT OPERATE
”
or a similar warning tag to the
ignition keyswitch before the engine is serviced.
Use one of the following methods to drain the engine
oil pan:
114
M0087475-06