If the service indicator does not reset easily, or if the
yellow core does not latch at the greatest vacuum,
the service indicator should be replaced. If the new
service indicator will not reset, the hole for the service
indicator may be restricted.
The service indicator may need to be replaced
frequently in environments that are severely dusty.
i02927289
Engine Air Precleaner - Check/
Clean
Illustration 46
g01453058
Typical engine air precleaner
(1) Wing nut
(2) Cover
(3) Body
Remove wing nut (1) and cover (2). Check for an
accumulation of dirt and debris in body (3). Clean the
body, if necessary.
After cleaning the precleaner, install cover (2) and
wing nut (1).
Note:
When the engine is operated in dusty
applications, more frequent cleaning is required.
i05277600
Engine Crankcase Breather
Element - Replace
NOTICE
Ensure that the engine is stopped before any servic-
ing or repair is performed.
1.
Place a container under canister (2).
2.
Clean the outside of the canister. Using a suitable
tool, remove the canister.
Illustration 47
g03348323
Typical example
3.
Lubricate O ring seal (1) on the new canister with
clean engine lubricating oil.
4.
Install the new canister. Spin on the canister until
the O ring seal contacts the base (3). Rotate the
canister ¾ of a full turn.
5.
Remove the container. Dispose of the old canister
and any split oil in accordance with local
regulations.
i02323089
Engine Mounts - Inspect
Note:
The engine mounts may not have been
supplied by Perkins . Refer to the OEM information
for further information on the engine mounts and the
correct bolt torque.
Inspect the engine mounts for deterioration and for
correct bolt torque. Engine vibration can be caused
by the following conditions:
• Incorrect mounting of the engine
• Deterioration of the engine mounts
• Loose engine mounts
SEBU8731
81
Maintenance Recommendations
Engine Air Precleaner - Check/Clean