i02330192
Monitoring System
Table 2
Warning Lamp
Shutdown
Lamp
Lamp Status
Description of lamp status
Engine Status
ON
ON
Lamp check
When the engine start switch is turned to the
“
ON
”
po-
sition both lamps will illuminate for 2 seconds only.
The engine has not been
started.
OFF
OFF
No faults
There are no active diagnostic faults.
The engine is running normally.
ON
OFF
Active diagnostic
fault
An active diagnostic fault has been detected.
The engine is running normally.
ON
FLASHING
Active diagnostic
fault
A serious active diagnostic fault has been detected and
an engine derate has been invoked.
The engine is running but the
engine has been derated.
FLASHING
OFF
Warning
One or more of the engine protection values has been
exceeded.
The engine is running normally.
FLASHING
FLASHING
Derate and
warning
One or more of the engine protection values has been
exceeded.
The engine is running but the
engine has been derated.
ON
ON
Engine shutdown One or more of the engine protection values has been
exceeded or a serious active diagnostic fault has been
detected.
The engine is shutdown or shut-
down is imminent.
i05546770
Monitoring System
If the Shutdown mode has been selected and the
warning indicator activates, engine shutdown
may take as little as 20 seconds from the time the
warning indicator is activated. Depending on the
application, special precautions should be taken
to avoid personal injury. The engine can be re-
started following shutdown for emergency ma-
neuvers, if necessary.
NOTICE
The Engine Monitoring System is not a guarantee
against catastrophic failures. Programmed delays
and derate schedules are designed to minimize false
alarms and provide time for the operator to stop the
engine.
The following parameters are monitored:
• Coolant temperature
• Intake manifold air temperature
• Intake manifold air pressure
• Oil pressure
• Pressure in the fuel rail
• Engine speed/timing
Programmable Options and
Systems Operation
If the Warning/Derate/Shutdown mode has been
selected and the warning indicator activates,
bring the engine to a stop whenever possible. De-
pending on the application, special precautions
should be taken to avoid personal injury.
The engine can be programmed to the following
modes:
SEBU9066
29
Features and Controls
Monitoring System
Содержание 1104D-E44T
Страница 106: ...2014 Perkins Engines Compony All Rights Reserved...