background image

 

N1015158 OPERATING MANUAL                              

 
 

 

Quality, Reliability and Safety 

 
 
This  equipment  has  been  designed  with  emphasis  on  QUALITY,  RELIABILITY  and 
SAFETY, and Perkin Elmer will accept responsibility for these aspects only if the following 
conditions are met: 
 
a) 

Electrical installation of the room or building in which the equipment is to be used 
must comply with regulations specified in the country where the equipment is to be 
used. 

 
b) 

The equipment must be used in accordance with the instructions for use provided 
by Perkin Elmer. 

 
c) 

All modifications and repairs to the equipment must be carried out by DBS or its 
authorised Agents. 

 
d) 

Modifications  must  not  be  carried  out  unless  they  conform  to  approved 
Engineering Service Information issued according to the appropriate Perkin Elmer 
procedure. 

 
e) 

The  equipment  installation  must  be  carried  out  in  accordance  with  local 
requirements for responsibility and warranty. 

 
 

1.3. Safety makings 

 
 

CE mark 

 
The "CE" mark for this product makes reference to the directives 
• 

89/336/EEC amended by 93/68/EEC for electromagnetic compatibility 

• 

73123/EEC amended by 93/68/EEC for low voltage 

 
 
 
COPYRIGHT 

All  rights  reserved.  The  information  contained  in  this  publication 
may  not  be  used  for  any  purpose  other  that  for  which  it  was 
originally supplied. The publication may not be reproduced in part 
or  in  whole  without  written  consent  of  Perkin  Elmer.  In  order  to 
maintain  and  improve  standards  of  manufacturing,  methods  of 
functioning  and  to  increase  reliability,  Perkin  Elmer  equipment  is 
periodically  reviewed.  For  this  reason,  the  contents  of  this 
publication  are  subject  to  change  without  notice.  The  equipment 
described is designed and manufactured by DBS. 

 

Содержание Peltier N1015158

Страница 1: ...rolled Fluid Circulator P N N1015158 Web address http las perkinelmer com OneSource Environmental directives htm Customer Care 1 800 762 4000 inside the USA 1 203 925 4602 outside the USA 0800 40 858...

Страница 2: ...1 Instrument description 4 2 2 N1015158 front and rear panel 5 2 3 Specifications 5 2 4 User interface 7 3 INSTALLATION 8 3 1 Checking the serial number 8 3 2 Checking main supply and fuses 8 3 3 Inst...

Страница 3: ...before starting any work inside the instrument Set the temperature to the required values on power on If using substances dangerous for health and the environment observe the laws and the standards i...

Страница 4: ...cording to the appropriate Perkin Elmer procedure e The equipment installation must be carried out in accordance with local requirements for responsibility and warranty 1 3 Safety makings CE mark The...

Страница 5: ...ferent metals The N1015158 provides temperatures ranging from 20 C to 60 C with 1 C stability and 0 1 C repeatability The features of the PCB 1500 include Peltier effect for heating and cooling the li...

Страница 6: ...et connections 2 3 Specifications 2 3 1 Keypad Display Unit The keypad display unit has a LCD screen All programmable parameters can be displayed in specific menus Three buttons are used to access the...

Страница 7: ...ed If using flammable or explosive substances take the necessary precautions Note Connection to the protective ground is ensured through the power supply cable which has to be in accordance with CEE 7...

Страница 8: ...The menu driven interface of the N1015158 allows the user to set the temperature and to view the configuration Three buttons are used to access the various functions and change the set parameters The...

Страница 9: ...inform Perkin Elmer immediately 3 2 Checking mains supply and fuses The N1015158 is factory set to operate at 220 VAC For operation at a voltage of 120 VAC the voltage selector at the rear of the cont...

Страница 10: ...sired value The new selected voltage will be now visible 3 3 Instrument set up 3 3 1 Start up The N1015158 is supplied completely assembled It is only necessary to make the appropriate connections Bef...

Страница 11: ...N1015158 has no special electrical external connections which would allow relay control etc Operations are performed either manually or via remote control using the USB connections Contact Perkin Elme...

Страница 12: ...it 1 only if the manual alarm reset option has been configured Menu page and functions of the buttons Menu Description L button Middle button R button Parameter User parameters Scroll Select Exit Conf...

Страница 13: ...equired to enter this menu CAUTION all these parameters are correctly set in the factory no changes should be made by the user Diagnostic parameters Description Unit of measure Cell temperature C Radi...

Страница 14: ...normal cleaning operations on the instrument only use a cloth dipped in water or neutral detergent do not use organic or abrasive solvents 5 2 Water level alarm Check for signs of water level It is re...

Страница 15: ...akage will be detected After the leakage is signalled on the N1015158 press the RESET ALARM button and remove the leakage immediately by checking all connections and fill up the system with distilled...

Страница 16: ...THE TANK WILL DROP AND WILL NEED TO BE TOPPED UP ONLY USE THE DISTILLED WATER SUPPLIED IN THE SEPARATE 200CC CONTAINER INSIDE THE PACKAGING TO TOP UP THE WATER IN THE UNIT Web address http las perkin...

Отзывы: