16
WARNING
If COFFEE CAPSULE is pierced more than once, upper needle may get
blocked by coffee grinds. Please use unfolded paper clip to clean it out.
Blockage of passageways.
When brewer is operated properly, it will not get blocked. If coffee capsule is used more than once it may create
blockage. To prevent passageway blockage please use coffee capsule once only. Open lid few seconds after
last drop had run out. Do not open lid prematurely. Coffee cartridge with piercing needle must be maintained
clean and without the dirt. Container below the cartridge must be periodically cleaned from dried up coffee.
Your Brewer has two capsule piercing needles. One on top, called inlet needle and one at the bottom, called
outlet needle. It also has long passageway from the brewer to the exit nozzle. If blockage occurs in the exit
nozzle , use unfolded paper clip to clean it out.To maintain proper operation make sure the both needles and
exit nozzle are kept clean.
Lower needle is not of tubular construction and does not go all the way through. It has U-shaped configuration
with slot on its side. This proprietary design makes clogging up this needle more difficult compared to
conventional design. If lower needle is blocked, wash cartridge under running water and use unfolded paper clip
to clean inside of the needle. It is not open all the way through. it has sealed end.
Coffee runs out out of the coffee capsule through the slot in the needle and then into the inside of the coffee
capsule using same slot. this way blockages are minimized and coffee runs out of the machine at lower
temperature. During the brew process water is very hot.
If upper, inlet nozzle get blocked use paper clip to clean. Needle has 3 openings around the central spike. Check
if the silicone seal on the upper piercing needle is properly installed.
Dispense few cups of water to rinse well. Clean with unfolded paper clip well. To dispense water only you will
need to open and close lid in order to send signal via sensor to control board. Never leave blocked needle for
more then 5 minutes, since blocked coffee will dry up and make it more difficult to remove.
A
B
B
A
If blockage occurs in the exit nozzle , use unfolded
paper clip to clean it out.
If upper, inlet nozzle get blocked use paper clip to
clean. Needle has 3 openings around the
central spike. Check if the silicone seal on the
upper piercing needle is properly installed.
Lower needle is not of tubular construction and
does not go all the way through. It has U-shaped
configuration with slot on its side.It has sealed
end. Coffee runs out out of the coffee capsule
through the slot in the needle and then into the
inside of the coffee capsule using same slot.