• Use the table to determine the minimum wire size (A.W.G.) extension cord.
• Use only 3-wire extension cords having 3-prong grounding type plugs and 3-pole receptacles which accept the tool plug.
• If the extension cord is worn, cut, or damaged in any way, replace it immediately.
Extension Cord Length (120V Operation)
Wire Size A.W.G.
Up to 25 ft. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Up to 50 ft. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
NOTE:
Using extension cords over 50 ft. long is not recommended.
Extension Cord Length (240V Operation)
Wire Size A.W.G.
Up to 50 ft. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
50 to 100 ft. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
100 to 200 ft. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
200 to 300 ft. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
NOTE:
Using extension cords over 300 ft. long is not recommended.
ELECTRICAL CONNECTIONS
WARNING:
All electrical connections must be performed by a qualified electrician. Make sure tool is off and disconnected
from power source before inspecting any wiring. The saw is prewired for use on a 120 volt, 60Hz power supply. The power lines
are inserted directly onto the switch. The green ground line must remain securely fastened to the frame to properly protect
against electrical shock.
• Remove the key to prevent unauthorized use.
INSTALLATION
_ 31 _