1
5
Enter motion profiles for deceleration, acceleration, velocity, and destination position (Position 1) that
are safe for your system and will demonstrate proper motion.
6
Click Go and confirm that the motion occurred in a stable and controlled fashion.
Congratulations! First time system verification for this axis is now complete. You should now initialize
all of the axes in your system. Go to Section
1.11.5, “Initializing Motion Axes,” on page
26 and repeat
the steps.
1.12 Developing User Application Code
Pro-Motion provides an intuitive, convenient, graphical interface to setup and exercise motion controllers such as
Prodigy/CME cards or ION
®
Digital Drives. Eventually though, you will begin to design application-specific software
code that will serve as your system controller. PMD supports two standard languages to accomplish this; Visual Basic,
through the set of Active-X libraries known as VB-Motion, and C/C++, through the source code-based system
known as C-Motion.
For more information on VB-Motion and C-Motion, please consult the
Magellan Motion Processor Programmer’s Command
Reference
.
1.12.1 Architecture
Figure 1-6 on page 29 shows two ways to locate your application code with the Prodigy/CME PC/104 cards.
Pro-Motion provides various selectable units for distance and time, but defaults to units of encoder counts (or
pulses for step motors) for distance and seconds for time. This means the default units for velocity are counts/
sec, and the default units for acceleration and deceleration are counts/sec
2
. So for a motor that has 2,000 counts
per rotation, to perform a symmetric trapezoidal move of 25 rotations with a top speed of 5 rotations per second
and with an acceleration time of two seconds, the parameters in the Trajectory dialog box would be set as follows:
Deceleration: 5,000 counts/sec
2
Acceleration: 5,000 counts/sec
2
Velocity: 10,000 counts/sec
Position 1: 0 counts
Position 2: 50,000 counts
Содержание PR8358120
Страница 6: ...vi Prodigy CME PC 104 User s Guide This page intentionally left blank ...
Страница 8: ...viii Prodigy CME PC 104 User s Guide This page intentionally left blank ...
Страница 56: ...Operation 56 Prodigy CME PC 104 User s Guide 2 This page intentionally left blank ...
Страница 68: ...Accessing Card Resources 68 Prodigy CME PC 104 User s Guide 3 This page intentionally left blank ...
Страница 88: ...Electrical Reference 88 Prodigy CME PC 104 User s Guide 4 This page intentionally left blank ...
Страница 98: ...Interconnect Module 98 Prodigy CME PC 104 User s Guide 5 This page intentionally left blank ...
Страница 102: ...102 Prodigy CME PC 104 User s Guide This page intentionally left blank ...