![Performance Motion Devices PR8358120 Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/performance-motion-devices/pr8358120/pr8358120_user-manual_1529622016.webp)
Installation
16
Prodigy/CME PC/104 User’s Guide
1
1.8.1
Resistor Pack Settings
The Prodigy/CME PC/104 card has minimal user-adjustable settings. Most settings are software configurable. To
prepare the card for installation, the user-specified resistor pack options should be checked, as described in the
following table.
1.8.2
Motor Output Configuration
There are two configurations for setting up the motor output pins on the Prodigy/CME PC/104 GP Connector:
These motor output pins can be set up for use with DC Brush, Brushless DC, and microstepping motors, or the motor
output pins can be set for pulse & direction motors. The default setting is for all motors to be set for DC Brush,
Brushless DC, and microstepping.
The switch bank SW1 controls these settings, which apply on a per-axis basis. The following table describes the correct
switch setting for each output type. Figure 1-3 on page 17 provides a diagram of SW1, and Figure 1-1 on page 15
shows the location of SW-1 on the Prodigy/CME PC/104 card.
SW1
back side
Motor output configuration
J1
front side
Extension Connector
J2
back side
Reserved
J3, J4
back side
Synch Connectors
J5, J6
front side
Right and Left Connectors
J9
front side
Option Connector
J12
front side
Pulse & Direction Connector
J15
front side
Ethernet Connector
J16
front side
CANbus Connector
J17
front side
Serial Connector
J19
front side
Reserved
J20
front side
Reserved
J21
front side
Power Connector
Item
Setting
Description
Resistor packs
RS1, RS2, RS3
Installed; this is the default setting of resistor
packs RS1 - RS3.
If differential connections are being used, leave these
resistor packs installed.
Removed
If single-ended encoder connections are being used,
remove the resistor packs.
Axis
Set for DC Brush, Brushless DC,
or Microstepping
Set for Pulse & Direction
1
1 on, 5 off
1 off, 5 on
2
2 on, 6 off
2 off, 6 on
3
3 on, 7 off
3 off, 7 on
4
4 on, 8 off
4 off, 8 on
Power to the card should be turned off when changing the state of the SW1 switches, and care should be taken
not to set both switch pairs on (for example both 1 and 5 on, or both 2 and 6 on etc.) or damage may occur to
the board.
Label
Located
Description
Содержание PR8358120
Страница 6: ...vi Prodigy CME PC 104 User s Guide This page intentionally left blank ...
Страница 8: ...viii Prodigy CME PC 104 User s Guide This page intentionally left blank ...
Страница 56: ...Operation 56 Prodigy CME PC 104 User s Guide 2 This page intentionally left blank ...
Страница 68: ...Accessing Card Resources 68 Prodigy CME PC 104 User s Guide 3 This page intentionally left blank ...
Страница 88: ...Electrical Reference 88 Prodigy CME PC 104 User s Guide 4 This page intentionally left blank ...
Страница 98: ...Interconnect Module 98 Prodigy CME PC 104 User s Guide 5 This page intentionally left blank ...
Страница 102: ...102 Prodigy CME PC 104 User s Guide This page intentionally left blank ...