background image

4

 BEFORE YOU BEGIN

Read these instructions completely and carefully. 

IMPORTANT

- Save these instructions.

IMPORTANT

- Observe all governing codes and 

ordinances.

Note to Installer

- Be sure to leave these instructions with 

the Consumer.

Note to Consumer

- Keep these instructions for future 

reference.

Skill level

- Installation of this appliance requires basic 

mechanical skills.

Completion time

- Approximately 1 hour.

We recommend that two people install this product.
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not 

covered under the Warranty.
You MUST use all supplied parts and use proper 

installation procedures as described in these 

instructions when installing this air conditioner.

CAUTION

Do not, under any circumstances, cut or remove the 

third (ground) prong from the power cord.
Do not change the plug on the power cord of the air 

conditioner.
Aluminum house wiring may present special problems- 

consult a qualified electrician.
When handling unit, be careful to avoid cuts from sharp 

metal edges and aluminum fins on front and rear coils.

REQUIRED TOOLS/HARDWARE

●  Pencil

●  Level

●  Tape measure

●  Socket wrenches

●  Phillips screwdriver

●  Adjustable wrench or pliers

●  Large flat blade screwdriver

HARDWARE

(Included - Packed with the Unit)

7/16 inch locking 

screw and flat washer 

for window panels

2 ea.

3/4 (or 1/2) inch Long 

Hex-head Screw

4

Safety Lock

1

3/4 inch Long Flat 

Head Bolt and 

Locknut

4 ea.

1/2 inch Long Screw 

and Locknut

2 ea.

Sill Angle Bracket

2

Long hex-head locking 

screw for tape angle, 

side retailer 5/16 inch 

long

10

Foam insert

2

Window sash seal 

foam

1

Insulation Panels

2

Weather stripping (10″ 

x 3/4″ x 1/12″)

5

INSTALLATION INSTRUCTIONS

Содержание 4PAC15000

Страница 1: ...WINDOW AIR CONDITIONER FOR MODEL 4PAC15000 4PAC18000 4PAC25000 Before using your air conditioner please read this manual carefully and keep it for future reference along with your receipt USER MANUAL...

Страница 2: ...___________________________ Purchase Date _____________________________________ Store Purchased ______________________________________ Installation Date ____________________________________ Installati...

Страница 3: ...ir or maintenance of this unit If necessary contact an installer for installation of this unit The air conditioner is not intended for use by young children without supervision Young children should b...

Страница 4: ...the unit Failure to do so may cause fire and electric shock DO NOT use the socket if it is loose or damaged Doing so may cause fire and electric shock DO NOT open the unit during operation Doing so m...

Страница 5: ...d of time unplug or turn OFF main power switch Leaving power on may cause unit failure or fire Do not place obstacles around air inlets or inside of air outlet Obstacles may cause appliance failure or...

Страница 6: ...sure the air conditioner has been securely and correctly installed according to the installation instructions in this manual Save this manual for possible future use in removing or installing this un...

Страница 7: ...Do not under any circumstances cut or remove the third ground prong from the power cord Do not change the plug on the power cord of the air conditioner Aluminum house wiring may present special proble...

Страница 8: ...or 31 Max Window Width 401 2 or 42 1 CHECK WINDOW OPENING SIZE The mounting parts furnished with this air conditioner are made to install in a wooden sill double hung window The standard parts are for...

Страница 9: ...ing screws from top of unit See Fig 5 8 Hold the cabinet while pulling on the base handle and carefully remove the unit 9 Add two foam inserts to holes in top of cabinet where shipping screws were rem...

Страница 10: ...panel frame into channel in the top angle and bottom rail Do this on both sides 4 Insert washer head locking 7 16 screws 2 into holes in top leg of filler panel frame See step 6 on next page Do not to...

Страница 11: ...adjust slope Fig 14 FIG 14 FIG 15A Mark About 11 2 to 15 8 Window Sash Side Louvers Sill Angle Bracket Window Sill Measure from the cabinet edge 5 FIG 15B Right Left Locknut 1 2 Log Screws and Locknut...

Страница 12: ...ne 3 4 or 1 2 long hex head screw A 3 4 or 1 2 long hex head screw B Left hand Window Filler Panel Top Leg C Window channel A 3 4 or 1 2 long hex head screw A A B C Window Sash Weather Seals FIG 18A F...

Страница 13: ...width in Step 10 1 Cut the insulation panel along the line Fig 21 or STEP 10 3 Slide the insulation panel you just cut into the accordion panel curtain The side of the insulation panel with the patte...

Страница 14: ...ill be installed by sounding wall or by magnetically finding nails 2 Cut or knock out a hole on each side of center stud 3 Measure between inside edges of every other stud as shown in Fig 1 NOTE Caref...

Страница 15: ...de If after proper installation condensation does not drain from the overflow drain hole during normal use adjust slope MASONRY CONSTRUCTION 1 Cut or build a wall opening in the masonry wall similar t...

Страница 16: ...all of its functions Afterwards follow the symbol for the functions you desire BEFORE operating the unit This unit can be controlled by the unit control or the remote control Remote Signal Receptor TO...

Страница 17: ...m AUTO COOL DRY HEAT for units with heating function and FAN The indicator light will be illuminated and remain on once the mode is selected The unit will automatically initiate the Energy Saver funct...

Страница 18: ...rection is obtained Move the levers from side to side until the desired Left Right direction is obtained ADDITIONAL THINGS YOU SHOULD KNOW The Cool circuit has an automatic 3 minute time delayed start...

Страница 19: ...m the filter clean NOTE Never use hot water over 104 F 40 C to clean the air filter Never attempt to operate the unit without the air filter CABINET CLEANING Be sure to unplug the air conditioner to p...

Страница 20: ...he coil set to FAN only mode Then set temperature to a higher setting AIR CONDITIONER CYCLING ON AND OFF TOO FREQUENTLY OR NOT ENOUGH Be sure unit is not too large or too small for the area of the roo...

Страница 21: ......

Страница 22: ......

Страница 23: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details...

Страница 24: ...Line Rd Suite 878 Dallas TX 75254 Distributed by 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User4PAC15000_4...

Отзывы: