background image

8

FIG. 13

Bottom 

Rail Seal

3/4

 (or 1/2

) long 

Hex-head Screw

 STEP 5:

INSTALL SUPPORT BRACKET

1.  Hold each support bracket flush against outside of 

sill & tighten to bottom of cabinet, as shown in Fig. 

15A. Mark brackets at top level of sill and remove.

2.  Assemble sill angle bracket to support brackets at 

the marked position. (See Fig. 15B.) Hand tighten, 

but allow for any changes later.

NOTE:

 Check that air conditioner is tilted back about 

ʺ

 to 1⅝

ʺ

 (tilted about 3º to 4º downward toward 

the outside). If, after proper installation, condensation 

does not drain from the overflow drain hole during 

normal use, adjust slope. (Fig 14)

FIG. 14

FIG. 15A

Mark

About 1

1

/

2

″ 

to 1

5

/

8

Window Sash

Side Louvers

Sill Angle Bracket

Window Sill

Measure from the 

cabinet edge.

5

FIG. 15B

 

Right

Left

Locknut

1/2

 Log Screws 

and Locknuts

2 Each Required for 

Each Support Bracket

Sill Angle 

Bracket

Flat Head 

Bolt

3.  Install support brackets (with sill angle brackets 

attached) to correct hole in bottom of cabinet, as 

shown in Fig. 16.

4.  Securely tighten all 6 bolts.

1/2

 Long 

Screws and 

Locknuts

 

FIG. 16

 STEP 6:

EXTEND WINDOW  

ACCORDION PANELS

1.  Carefully raise window to expose accordion panel 

locking screws. Loosen screws so accordion 

panels slide easily.

2. Extend panels to fill window opening completely. 

Tighten locking screws on top (Fig. 17A).

3. Close window behind top angle.

Locking Screw

7/16

 Locking 

Screw and 

Washer

FIG. 17A

Содержание 4PAC15000

Страница 1: ...WINDOW AIR CONDITIONER FOR MODEL 4PAC15000 4PAC18000 4PAC25000 Before using your air conditioner please read this manual carefully and keep it for future reference along with your receipt USER MANUAL...

Страница 2: ...___________________________ Purchase Date _____________________________________ Store Purchased ______________________________________ Installation Date ____________________________________ Installati...

Страница 3: ...ir or maintenance of this unit If necessary contact an installer for installation of this unit The air conditioner is not intended for use by young children without supervision Young children should b...

Страница 4: ...the unit Failure to do so may cause fire and electric shock DO NOT use the socket if it is loose or damaged Doing so may cause fire and electric shock DO NOT open the unit during operation Doing so m...

Страница 5: ...d of time unplug or turn OFF main power switch Leaving power on may cause unit failure or fire Do not place obstacles around air inlets or inside of air outlet Obstacles may cause appliance failure or...

Страница 6: ...sure the air conditioner has been securely and correctly installed according to the installation instructions in this manual Save this manual for possible future use in removing or installing this un...

Страница 7: ...Do not under any circumstances cut or remove the third ground prong from the power cord Do not change the plug on the power cord of the air conditioner Aluminum house wiring may present special proble...

Страница 8: ...or 31 Max Window Width 401 2 or 42 1 CHECK WINDOW OPENING SIZE The mounting parts furnished with this air conditioner are made to install in a wooden sill double hung window The standard parts are for...

Страница 9: ...ing screws from top of unit See Fig 5 8 Hold the cabinet while pulling on the base handle and carefully remove the unit 9 Add two foam inserts to holes in top of cabinet where shipping screws were rem...

Страница 10: ...panel frame into channel in the top angle and bottom rail Do this on both sides 4 Insert washer head locking 7 16 screws 2 into holes in top leg of filler panel frame See step 6 on next page Do not to...

Страница 11: ...adjust slope Fig 14 FIG 14 FIG 15A Mark About 11 2 to 15 8 Window Sash Side Louvers Sill Angle Bracket Window Sill Measure from the cabinet edge 5 FIG 15B Right Left Locknut 1 2 Log Screws and Locknut...

Страница 12: ...ne 3 4 or 1 2 long hex head screw A 3 4 or 1 2 long hex head screw B Left hand Window Filler Panel Top Leg C Window channel A 3 4 or 1 2 long hex head screw A A B C Window Sash Weather Seals FIG 18A F...

Страница 13: ...width in Step 10 1 Cut the insulation panel along the line Fig 21 or STEP 10 3 Slide the insulation panel you just cut into the accordion panel curtain The side of the insulation panel with the patte...

Страница 14: ...ill be installed by sounding wall or by magnetically finding nails 2 Cut or knock out a hole on each side of center stud 3 Measure between inside edges of every other stud as shown in Fig 1 NOTE Caref...

Страница 15: ...de If after proper installation condensation does not drain from the overflow drain hole during normal use adjust slope MASONRY CONSTRUCTION 1 Cut or build a wall opening in the masonry wall similar t...

Страница 16: ...all of its functions Afterwards follow the symbol for the functions you desire BEFORE operating the unit This unit can be controlled by the unit control or the remote control Remote Signal Receptor TO...

Страница 17: ...m AUTO COOL DRY HEAT for units with heating function and FAN The indicator light will be illuminated and remain on once the mode is selected The unit will automatically initiate the Energy Saver funct...

Страница 18: ...rection is obtained Move the levers from side to side until the desired Left Right direction is obtained ADDITIONAL THINGS YOU SHOULD KNOW The Cool circuit has an automatic 3 minute time delayed start...

Страница 19: ...m the filter clean NOTE Never use hot water over 104 F 40 C to clean the air filter Never attempt to operate the unit without the air filter CABINET CLEANING Be sure to unplug the air conditioner to p...

Страница 20: ...he coil set to FAN only mode Then set temperature to a higher setting AIR CONDITIONER CYCLING ON AND OFF TOO FREQUENTLY OR NOT ENOUGH Be sure unit is not too large or too small for the area of the roo...

Страница 21: ......

Страница 22: ......

Страница 23: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details...

Страница 24: ...Line Rd Suite 878 Dallas TX 75254 Distributed by 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User4PAC15000_4...

Отзывы: