B. Drive 3/4

"

 (19 mm) or 1/2

"

 (12.7 mm) 

locking screws through frame holes into window 

sash (Fig. 8).

         

Fig. 8

C. To secure lower sash in place, attach right 

angle sash lock with 3/4

"

 (19 mm) or 1/2

"

 

(12.7 mm) screw as shown (Fig. 9).

Fig. 9

 D. Cut Window sash seal foam and insert it in the 

 space between the upper and lower sashes 

(Fig. 10).

Fig. 10

FOAM SEAL

If AC is Blocked by Stor m Window

Add wood as shown in Fig.11, or remove storm 

window before air conditioner is installed.

If Storm Window Frame must remain, be sure the

drain holes or slots are not caulked or painted 

shut.Accumulated rain water or condensation 

must be allowed to drain out.

Removing AC From Window

● Turn AC off, and disconnect power cord.

● Remove sash seal from between windows, and 

   unscrew safety sash lock.

● Remove screws installed through frame and 

   frame-lock.

● Close (slide) side panels into frame.

● Keeping a firm grip on air conditioner, raise sash

   and carefully remove. 

● Be careful not to spill any remaining water 

   while lifting unit from window. Store parts WITH   

   air conditioner.

        

       

Board 

thickness

as required, 

for proper 

pitch to rear, 

along entire

sill. Fasten 

with nails or 

screws. 

Fig. 11

Storm window

frame or other

obstruction.

SASH

1-1/2

"

 min

(38 mm)

INSTALLATION INSTRUCTIONS (CONTINUED)

12

Содержание 3PES5000

Страница 1: ...fore using your window air conditioner please read this manual carefully and keep it for future reference along with your receipt Your Source for Home Comfort FOR MODEL 3PES5000 WINDOW AIR CONDITIONER...

Страница 2: ...ion of this unit if necessary The air conditioner is not intended for use by young children without supervision Young children should be supervised to ensure that they do not play with the air conditi...

Страница 3: ...ause explosion fire and burns Doing so may cause electric shock or fire due to heat generation Doing so may cause electric shock Doing so may cause failure of machine or electric shock Doing so may ca...

Страница 4: ...f time turn OFF main power switch If water enters the unit turn the unit off at the power outlet and switch off the circuit breaker Isolate supply by taking the power plug out and contact a qualified...

Страница 5: ...our Safety Electrical Information The power supply must be replaced if it fails to reset when either the TEST button is pushed or it cannot be reset DO NOT store or use gasoline or other flammable vap...

Страница 6: ...pinging or switching sounds Vibration Unit may vibrate and make noise because of poor wall or window construction or incorrect installation ELECTRONIC CONTROL OPERATING INSTRUCTIONS TEMP TIMER Check F...

Страница 7: ...Auto mode To operate on Fan only Use this function only when cooling is not desired such as for room air circulation or to exhaust stale air You can choose any fan speed you prefer During this functi...

Страница 8: ...s after the mode is selected The temperature will then increase cooling or decrease heating units with heater only by another 2O F 1 2O C after an additional 30 minutes This new temperature will be ma...

Страница 9: ...ror Unplug the unit and plug it back in If error repeats call consumer services Evaporator temperature sensor error Unplug the unit and plug it back in If error repeats call consumer services is displ...

Страница 10: ...nditioner BEFORE YOU BEGIN Do not under any circumstances cut or remove the third ground prong from the power cord CAUTION Do not change the plug on the power cord of the air conditioner Aluminum hous...

Страница 11: ...zation and drainage If you are not using the side panels for any reason this pitch to the rear must be maintained A Place unit on floor a bench or a table Hold the accordion panel in one hand and gent...

Страница 12: ...g 5 Carefully close the window behind the top rail of the unit Fig 5 NOTE Check that air conditioner is tilted back about 5 8 to 3 4 tilted about 3O to 4O downward to the outside After proper installa...

Страница 13: ...slots are not caulked or painted shut Accumulated rain water or condensation must be allowed to drain out Removing AC From Window Turn AC off and disconnect power cord Remove sash seal from between w...

Страница 14: ...loth before wiping the controls Excess water in or around the controls may cause damage to the air conditioner Plug in air conditioner after unit has dried completely If air conditioner will be stored...

Страница 15: ...F 18 C To defrost the coil set to Fan Only mode Air filter may be dirty Clean filter Refer to Care and Cleaning section To defrost set to Fan Only mode Thermostat is set too cold for night time coolin...

Страница 16: ...for Home Comfort Distributed by Perfect Aire LLC 5151 Belt Line Rd Suite 878 Dallas TX 75254 Specification and performance data is subject to change without notice Printed in China 877 365 6274 www pe...

Отзывы: