background image

9

NORMAL SOUNDS

AIR CONDITIONER FEATURES

VIBRATION

Unit may vibrate and make 

noise because of poor wall or 

window construction or incorrect 

installation. This DOES NOT 

indicate a defective unit.

PINGING OR SWITCHING

Droplets of water hitting 

condenser during normal 

operation may cause “pinging” 

or “switching” sounds.

HIGH PITCHED CHATTER

High efficiency compressors 

may have a high pitched chatter 

during the cooling cycle.

SOUND OF RUSHING AIR

At the front of the unit, 

the sound of rushing air 

being moved by the fan 

may be heard.

GURGLE/HISS

“Gurgling” or “hissing” 

noise may be heard due 

to refrigerant passing 

through evaporator during 

normal operation.

NOTE: 

All of the pictures in this manual are for explanatory purposes only. The actual shape/look of 

the air conditioner purchased may be slightly different, but the operations and functions are similar.

Thoroughly familiarize yourself with the control panel shown below and all of its functions. Afterwards, follow the  

symbol for the functions you desire BEFORE operating the unit. This unit can be controlled by the unit control or the 

remote control.

Remote Signal 

Receptor

 TO TURN UNIT ON OR OFF:

Press

 

 ON/OFF button to turn the unit on or off.

NOTE: 

The unit will automatically initiate the Energy Saver 

function under COOL, DRY and AUTO (only AUTO-COOLING 

and AUTO-FAN modes).

 TO CHANGE TEMPERATURE SETTING:

Press 

/

 UP/DOWN buttons to change the  

temperature setting. 

NOTE: 

Press or hold either UP (

) or DOWN (

) button 

until the desired temperature is shown on the display. The 

temperature will be automatically maintained anywhere 

between 62°F (17°C) and 86°F (30°C). If you want the display 

to read the actual room temperature, see “To Operate on Fan 

Only” section.

 TO ADJUST FAN SPEEDS:

Press

 

 

to select the Fan Speed in four steps: Auto, Low, 

Med or High. Each time the button is pressed, the fan speed 

is shifted. In DRY mode, the fan speed is controlled at Low 

automatically. For some models with heating capabilities, the 

fan speed cannot be adjusted while in HEAT mode.

UNIT CONTROL PANEL

Heat indicator on models with 

heating capabilities only.

 

Auto

Low

Med

High

Auto

Cool
Dry

Fan

TEMP/TIMER

On

Off

Sleep

Timer

Mode

Check

Filter

Energy

Saver

Fan

Follow

Me

Heat

Содержание 3PACH12000

Страница 1: ...DITIONER FOR MODEL 3PACH8000 WITH ELECTRIC HEAT 3PACH12000 WITH ELECTRIC HEAT Before using your air conditioner please read this manual carefully and keep it for future reference along with your recei...

Страница 2: ...___________________________ Purchase Date _____________________________________ Store Purchased ______________________________________ Installation Date ____________________________________ Installati...

Страница 3: ...for installation of this unit if necessary The air conditioner is not intended for use by young children without adult supervision Young children should be supervised to ensure that they do not play w...

Страница 4: ...the unit Failure to do so may cause fire and electric shock DO NOT use the socket if it is loose or damaged Doing so may cause fire and electric shock DO NOT open the unit during operation Doing so m...

Страница 5: ...d of time unplug or turn OFF main power switch Leaving power on may cause unit failure or fire DO NOT place obstacles around air inlets or inside of air outlet Obstacles may cause appliance failure or...

Страница 6: ...curely and correctly installed according to the installation instructions in this manual Save this manual for possible future use in removing or installing this unit When handling the air conditioner...

Страница 7: ...ll the unit To prevent injury or strain use proper lifting and carrying techniques when moving unit Carefully inspect location where air conditioner will be installed Be sure it will support the weigh...

Страница 8: ...liquid soap over the adhesive with your fingers Wipe with warm water and dry Do not use sharp instruments rubbing alcohol flammable fluids or abrasive cleaners to remove tape or glue These products c...

Страница 9: ...the above steps for the left hand accordion panel STEP 4 ATTACH FOAM ADHESIVE SEAL Attach foam adhesive seal along the bottom of the accordion panel s bottom channel A B STEP 5 INSTALL CABINET INTO W...

Страница 10: ...ioner cabinet is tilted back to 1 to 1 3 4 so that water can run to the outside Fig 13 STEP 6 ATTACH ACCORDION PANELS TO WINDOW FRAMES 1 Extend the accordion panels out against the window frame Fig 11...

Страница 11: ...to the window sash Fig 15 4 Attach the window lock bracket to the window sash with two 10 x 3 4 or 1 2 round head screws to secure window in place Fig 15 A B C D A Window lock bracket B Upper window g...

Страница 12: ...ou desire BEFORE operating the unit This unit can be controlled by the unit control or the remote control Remote Signal Receptor TO TURN UNIT ON OR OFF Press ON OFF button to turn the unit on or off N...

Страница 13: ...units with heating function and FAN The indicator light will be illuminated and remain on once the mode is selected The unit will automatically initiate the Energy Saver function under COOL DRY and A...

Страница 14: ...direction is obtained Move the center handles from side to side until the desired Left Right direction is obtained ADDITIONAL THINGS YOU SHOULD KNOW The Cool circuit has an automatic 3 minute time de...

Страница 15: ...over 104 F 40 C to clean the air filter Never attempt to operate the unit without the air filter CABINET CLEANING Be sure to unplug the air conditioner to prevent shock or fire hazard The cabinet and...

Страница 16: ...oil set to FAN only mode Then set temperature to a higher setting AIR CONDITIONER CYCLING ON AND OFF TOO FREQUENTLY OR NOT ENOUGH Be sure unit is not too large or too small for the area of the room Re...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...elt Line Rd Suite 878 Dallas TX 75254 Distributed by 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User_3PACH8...

Отзывы: