background image

1

WARNINGS

Plug in power cord properly.

Failure to do so may cause electric shock or fire due to 

excess heat generation.

DO NOT

 operate or stop the unit by inserting or pull-

ing out the power plug directly from the wall.

Doing so may cause electric shock or fire due to  

heat generation.

DO NOT

 use a damaged power cord.

Doing so may cause electric shock or fire. If the power 

cord is damaged, it must be replaced by the manufactur-

er or an authorized service center or a similarly qualified 

person in order to avoid a hazard.

DO NOT

 modify power cord length or share the 

outlet with other appliances.

Doing so may cause electric shock or fire due to  

heat generation.

DO NOT

 operate with wet hands or in  

damp environment.

Doing so may cause electric shock.

DO NOT

 direct airflow directly at room occupants.

This could cause health issues.

Always ensure effective grounding.

Incorrect grounding may cause electric shock.

DO NOT

 allow water to run into electric parts.

Doing so may cause failure of machine or electric shock.

Always install circuit breaker and a dedicated 

power circuit.

Incorrect installation may cause fire and electric shock.

Always unplug the unit if strange sounds, smell or 

smoke comes from the unit.

Failure to do so may cause fire and electric shock.

DO NOT

 use the socket if it is loose or damaged.

Doing so may cause fire and electric shock.

DO NOT

 open the unit during operation.

Doing so may cause electric shock.

DO NOT

 use firearms near unit.

Doing so may cause fire.

DO NOT 

use the power cord close to  

heating appliances.

Doing so may cause fire and electric shock.

DO NOT 

disassemble, modify, or drill holes into  

the air conditioner.

Doing so may cause failure and electric shock and void 

the manufacturer’s warranty.

Ventilate room before operating air conditioner if 

there is a gas leak from another appliance such as 

a stove.

Failure to do so may cause explosion, fire and burns.

DO NOT

 use the power cord near flammable gas or 

combustibles, such as gasoline, benzene, thinner, etc.

Doing so may cause an explosion or fire.

READ SAFETY PRECAUTIONS BEFORE INSTALLATION

To prevent injury to the user or other people and property damage, the following instructions must be followed.  

Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the 

following indications.

THIS SYMBOL INDICATES THAT IGNORING INSTRUCTIONS MAY CAUSE 

DEATH OR SERIOUS INJURY.

NEVER DO THIS.

OTHER SYMBOLS:

ALWAYS DO THIS.

THIS SYMBOL INDICATES THAT IGNORING INSTRUCTIONS MAY CAUSE 

MODERATE INJURY TO YOUR PERSON, OR DAMAGE TO YOUR UNIT OR 

OTHER PROPERTY.

SAFETY PRECAUTIONS

Содержание 3PACH12000

Страница 1: ...DITIONER FOR MODEL 3PACH8000 WITH ELECTRIC HEAT 3PACH12000 WITH ELECTRIC HEAT Before using your air conditioner please read this manual carefully and keep it for future reference along with your recei...

Страница 2: ...___________________________ Purchase Date _____________________________________ Store Purchased ______________________________________ Installation Date ____________________________________ Installati...

Страница 3: ...for installation of this unit if necessary The air conditioner is not intended for use by young children without adult supervision Young children should be supervised to ensure that they do not play w...

Страница 4: ...the unit Failure to do so may cause fire and electric shock DO NOT use the socket if it is loose or damaged Doing so may cause fire and electric shock DO NOT open the unit during operation Doing so m...

Страница 5: ...d of time unplug or turn OFF main power switch Leaving power on may cause unit failure or fire DO NOT place obstacles around air inlets or inside of air outlet Obstacles may cause appliance failure or...

Страница 6: ...curely and correctly installed according to the installation instructions in this manual Save this manual for possible future use in removing or installing this unit When handling the air conditioner...

Страница 7: ...ll the unit To prevent injury or strain use proper lifting and carrying techniques when moving unit Carefully inspect location where air conditioner will be installed Be sure it will support the weigh...

Страница 8: ...liquid soap over the adhesive with your fingers Wipe with warm water and dry Do not use sharp instruments rubbing alcohol flammable fluids or abrasive cleaners to remove tape or glue These products c...

Страница 9: ...the above steps for the left hand accordion panel STEP 4 ATTACH FOAM ADHESIVE SEAL Attach foam adhesive seal along the bottom of the accordion panel s bottom channel A B STEP 5 INSTALL CABINET INTO W...

Страница 10: ...ioner cabinet is tilted back to 1 to 1 3 4 so that water can run to the outside Fig 13 STEP 6 ATTACH ACCORDION PANELS TO WINDOW FRAMES 1 Extend the accordion panels out against the window frame Fig 11...

Страница 11: ...to the window sash Fig 15 4 Attach the window lock bracket to the window sash with two 10 x 3 4 or 1 2 round head screws to secure window in place Fig 15 A B C D A Window lock bracket B Upper window g...

Страница 12: ...ou desire BEFORE operating the unit This unit can be controlled by the unit control or the remote control Remote Signal Receptor TO TURN UNIT ON OR OFF Press ON OFF button to turn the unit on or off N...

Страница 13: ...units with heating function and FAN The indicator light will be illuminated and remain on once the mode is selected The unit will automatically initiate the Energy Saver function under COOL DRY and A...

Страница 14: ...direction is obtained Move the center handles from side to side until the desired Left Right direction is obtained ADDITIONAL THINGS YOU SHOULD KNOW The Cool circuit has an automatic 3 minute time de...

Страница 15: ...over 104 F 40 C to clean the air filter Never attempt to operate the unit without the air filter CABINET CLEANING Be sure to unplug the air conditioner to prevent shock or fire hazard The cabinet and...

Страница 16: ...oil set to FAN only mode Then set temperature to a higher setting AIR CONDITIONER CYCLING ON AND OFF TOO FREQUENTLY OR NOT ENOUGH Be sure unit is not too large or too small for the area of the room Re...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...elt Line Rd Suite 878 Dallas TX 75254 Distributed by 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User_3PACH8...

Отзывы: