background image

3

When removing air filter, do not 
touch metal parts of the unit.

Doing so may cause an injury.

.

Cleaning unit when power is ON 
may cause fire and electric shock
and may cause an injury. 

Operation with windows open may
cause moisture to enter the room.

 

 

 

 

Stop operation and close the
window in severe storms or 
hurricanes.

Do not clean with water.

Water may enter the unit and 
degrade the insulation causing an 
electric shock.

This could injure the pet or plant.

Failure to do so may cause electric

shock and damage.

Do not put a pet or house plant 
where it will be exposed to 
direct air flow.

Hold the plug by the head of the
power plug when taking it out.

Ensure proper ventilation 
especially in rooms with a stove 
or other appliances.

Failure to do so may result in an
oxygen shortage.

This unit is NOT intended to 

preserve precision devices, food, 

pets, plants, and art objects. It may

cause deterioration of quality, etc.

Leaving power on may cause unit 
failure or fire.

Use only as intended.

If unit will not be used for a long
period of time, turn OFF main 
power switch.

 

 

 

 

 

 

If water enters the unit, turn the unit off at the power 
outlet and switch off the circuit breaker. Isolate supply
by taking the power-plug out and contact a qualified 
serviced technician. 

Obstacles may cause appliance 
failure or accident.

Cleaners or detergents may change 
the color or scratch the surface of
the unit.

Do not place obstacles around 
air-inlets or inside of air-outlet.

Use only a soft cloth to clean
the unit.

Prolonged exposure to outdoor
elements may cause damage to
installation bracket causing unit to fall.

There is danger of electric shock.

Periodically check installation
bracket for damage.

.

Operation without secured filters
may cause failure. A dirty filter 
can cause the unit to not run efficiently.

Water from unit contains 
contaminants and could cause 
illness.

Always insert the filters securely. 
Clean filter AT LEAST once 
every two weeks.

NEVER drink water drained from
air conditioner.

Unit and Circuit breaker/fuse
must be switched OFF when
cleaning. 

Do not place heavy objects on the power cord 
and always ensure that the cord is not 
compressed.

Use caution when unpacking 
and installing. 

Sharp edges could cause injury.

!

!

!

!

!

!

!

!

!

!

!

There is danger of fire or electric shock.

!

CAUTION

 

Electrical Shock and 

Personal Injury Hazard

 

Meeting Electrical Requirements

WARNING

!

• Electrical ground is required on this appliance.

• DO NOT ground  to a gas line.

• If cold water pipe is interrupted by using plastic, non-

metallic gaskets, or other insulating materials. DO NOT use 

for grounding.

• Check with a qualified electrician if you are in doubt as to 

whether the appliance is properly grounded.

• DO NOT modify power supply cord plug. If it does not fit the 

outlet, have a proper outlet installed by a qualified electrician.

• DO NOT have a fuse in the neutral or grounding circuit. 

A fuse in the neutral, or grounding circuit could result in an 

electrical shock.

• DO NOT use an extension cord with this appliance.

Failure

 

to

 

follow these instructions could result 

in electrical shock, serious injury, or death.

Observe all local governing codes and ordinances.

Do not, under any circumstances, remove the power

supply cord grounding prong.

NOTE: 

If codes permit, and a separate grounding wire is used,

it is recommended that a qualified electrician determine that the

grounding path is adequate and not interrupted by plastic, 

non-metallic gaskets, or other insulating materials.

Receptacle Wiring

Receptacle wiring should be a minimum of 14 gauge. Use copper 

wire only. It is your responsibility to provide proper and adequate

receptacle wiring, installed by a qualified electrician.

Electrical Requirements

A time delay fuse or time delay circuit breaker is also required. A

separate circuit, serving only this appliance, MUST be provided.  

Содержание 3PAC15000

Страница 1: ...it for future reference along with your receipt Your Source for Home Comfort WINDOW AIR CONDITIONER USER MANUAL 17 800 18 500 25 000 28 500 BTU FOR MODELS PAHP18002 with 16 000 BTU heat pump PACH18000...

Страница 2: ...The air conditioner is not intended for use by young children without supervision Young children should be supervised to ensure that they do not play with the air conditioner Disabled persons may req...

Страница 3: ...se explosion fire and burns Doing so may cause electric shock or fire due to heat generation Doing so may cause electric shock Doing so may cause failure of machine or electric shock Doing so may caus...

Страница 4: ...from unit contains contaminants and could cause illness Always insert the filters securely Clean filter AT LEAST once every two weeks NEVER drink water drained from air conditioner Unit and Circuit b...

Страница 5: ...zed repairman Operation of Current Device 1 Plug in the air conditioner 2 The power supply cord will have TWO buttons on the plug head Press the TEST button The RESET button will click as it pops out...

Страница 6: ...familiarize yourself with the control panel as shown below and all its functions Then follow the symbol for the functions you desire The unit can be controlled by the unit controls alone or with the...

Страница 7: ...the Cool mode the unit display indicates the set temperature This feature can ONLY be activated from the remote control The remote control serves as a remote thermostat allowing for precise temperatur...

Страница 8: ...minute time delayed start if the unit is turned off and on quickly After unit is turned off leave unit off for a minimum of 3 minutes before attempting to turn back on This prevents overheating of the...

Страница 9: ...p these instructions for future reference Note to Installer Be sure to leave these instructions with the Consumer Completion time Approximately 1 hour Skill level Installation of this appliance requir...

Страница 10: ...pes or blinds will not stop proper airflow 5 Check the available electrical service Power supply MUST be the same as that shown on the unit serial nameplate Power cord is 48 inches long Be sure you ha...

Страница 11: ...the base if installed See Fig 5 8 Hold the cabinet while pulling on the base handle and carefully remove the unit 9 Add two foam inserts to holes in top of cabinet where shipping screws were removed...

Страница 12: ...center of window sill See Fig 10 2 Place cabinet in window with bottom sill angle firmly seated over window sill as shown See Fig 10A Bring window down temporarily behind top angle to hold cabinet in...

Страница 13: ...refully slide into cabinet leaving 6 inches protruding 2 DO NOT push on controls or finned coils 3 Be sure chassis is firmly seated towards rear of cabinet 4 Installation of front is the reverse of re...

Страница 14: ...frame construction at ends of windows under truss bearing points etc can be installed stud nearest the center of area where air conditioner thickness of framing material used thickness of framing mate...

Страница 15: ...a wall opening in the masonry wall similar to the frame construction refer to Step 2 of Thru The Wall Installation for wall thickness greater than 8 1 2 2 Secure cabinet in place using masonry nails o...

Страница 16: ...the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or with a cloth dampened in a solution of warm water and mild liquid dishwashing deterge...

Страница 17: ...re and Cleaning section To defrost set to Fan Only mode Thermostat is set too cold for night time cooling To defrost the coil set to Fan Only mode Then set temperature to a higher setting UNIT WILL NO...

Страница 18: ...for Home Comfort Distributed by Perfect Aire LLC 5151 Belt Line Rd Suite 878 Dallas TX 75254 Specification and performance data is subject to change without notice Printed in PRC 877 365 6274 www per...

Отзывы: