IMPORTANT SAFETY INSTRUCTIONS

Be sure the electrical service is adequate for the model you have  chosen. 
This information can be found on the serial plate, which is located on the 
side of the cabinet and behind the grill.

Be sure the air conditioner is properly grounded. To minimize shock and fire 
hazards, proper grounding is important. The power cord is equipped with a 
three-prong grounding plug for protection against shock hazards.
Your air conditioner must be used in a properly grounded wall receptacle. If 
the wall receptacle you intend to use is not adequately grounded or 

protected by a time delay fuse or circuit breaker, have a qualified electrician 

install the proper receptacle. 
Ensure the receptacle is accessible after the unit installation.
Do not run air conditioner without side protective cover in place. This could 
result in mechanical damage within the air conditioner. 

Do not use an extension cord or an adaptor plug.

WARNING!  

DO NOT store or use gasoline or other flammable vapors or liquids in 

the vicinity of this or any other appliance.

Avoid fire hazard or electric shock. DO NOT use an extension cord or 

an adaptor plug. DO NOT remove any prong from the power cord.

WARNING! 

NOTE  

The power supply cord with

this air conditioner contains a current 

detection device designed to reduce 

the risk of fire.

Please refer to    

the section "Operation 

of Current Device" (below) for details.

In the event that the power supply cord 

is damaged, it MUST be replaced by 

an authorized repairman.

Operation of Current Device

1. Plug in the air conditioner.

2. The power supply cord will have TWO buttons on the plug head. Press the TEST

button. The RESET button will click as it pops out.

3. Press the RESET button; again you will notice a click as the button engages.

4. The power supply cord is now supplying electricity to the unit.

(On some products this is also indicated by a light on the plug head.)

           

                 

     

      

NOTES:

Do not use this device to turn the unit on or off.

Always make sure the RESET button is pushed in for correct operation.

If power supply cord is damaged, it cannot be repaired. Please call customer service to assist with replacement. 

 

TEST

RESET

Plug in &

press RESET

NOTE: Some plugs have

            buttons on the top.

DO NOT, under any

circumstances, cut,

remove, or bypass

grounding prong.

Power supply cord

with 3-prong grounding plug

and current detection device

The power supply cord contains a current device that senses damage to the power 
cord. To test your power supply cord do the following:   

NOTE:

This air conditioner is designed to be operated under conditions as follows:

If the unit is operated beyond the conditions specified above, it may cause a failure of the unit.

Cooling operation

Heating operation

Outdoor temp:  18-43°C/64-109°F (18-52°C/64-125°F for special tropical models)

Indoor temp: 

17-32°C/62-90°F

Outdoor temp:  -5-24°C/23-76°F

Indoor temp: 

0-27°C/32-80°F

For Your Safety

Electrical Information

4

*Please note that not all units come with a heating element. The “Heating operation” specifications only 

 apply for units that DO have a heating element.

The power supply must be replaced if it fails to reset when either the TEST button is pushed or it cannot be reset. 

Содержание 3PAC15000

Страница 1: ...it for future reference along with your receipt Your Source for Home Comfort WINDOW AIR CONDITIONER USER MANUAL 17 800 18 500 25 000 28 500 BTU FOR MODELS PAHP18002 with 16 000 BTU heat pump PACH18000...

Страница 2: ...The air conditioner is not intended for use by young children without supervision Young children should be supervised to ensure that they do not play with the air conditioner Disabled persons may req...

Страница 3: ...se explosion fire and burns Doing so may cause electric shock or fire due to heat generation Doing so may cause electric shock Doing so may cause failure of machine or electric shock Doing so may caus...

Страница 4: ...from unit contains contaminants and could cause illness Always insert the filters securely Clean filter AT LEAST once every two weeks NEVER drink water drained from air conditioner Unit and Circuit b...

Страница 5: ...zed repairman Operation of Current Device 1 Plug in the air conditioner 2 The power supply cord will have TWO buttons on the plug head Press the TEST button The RESET button will click as it pops out...

Страница 6: ...familiarize yourself with the control panel as shown below and all its functions Then follow the symbol for the functions you desire The unit can be controlled by the unit controls alone or with the...

Страница 7: ...the Cool mode the unit display indicates the set temperature This feature can ONLY be activated from the remote control The remote control serves as a remote thermostat allowing for precise temperatur...

Страница 8: ...minute time delayed start if the unit is turned off and on quickly After unit is turned off leave unit off for a minimum of 3 minutes before attempting to turn back on This prevents overheating of the...

Страница 9: ...p these instructions for future reference Note to Installer Be sure to leave these instructions with the Consumer Completion time Approximately 1 hour Skill level Installation of this appliance requir...

Страница 10: ...pes or blinds will not stop proper airflow 5 Check the available electrical service Power supply MUST be the same as that shown on the unit serial nameplate Power cord is 48 inches long Be sure you ha...

Страница 11: ...the base if installed See Fig 5 8 Hold the cabinet while pulling on the base handle and carefully remove the unit 9 Add two foam inserts to holes in top of cabinet where shipping screws were removed...

Страница 12: ...center of window sill See Fig 10 2 Place cabinet in window with bottom sill angle firmly seated over window sill as shown See Fig 10A Bring window down temporarily behind top angle to hold cabinet in...

Страница 13: ...refully slide into cabinet leaving 6 inches protruding 2 DO NOT push on controls or finned coils 3 Be sure chassis is firmly seated towards rear of cabinet 4 Installation of front is the reverse of re...

Страница 14: ...frame construction at ends of windows under truss bearing points etc can be installed stud nearest the center of area where air conditioner thickness of framing material used thickness of framing mate...

Страница 15: ...a wall opening in the masonry wall similar to the frame construction refer to Step 2 of Thru The Wall Installation for wall thickness greater than 8 1 2 2 Secure cabinet in place using masonry nails o...

Страница 16: ...the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or with a cloth dampened in a solution of warm water and mild liquid dishwashing deterge...

Страница 17: ...re and Cleaning section To defrost set to Fan Only mode Thermostat is set too cold for night time cooling To defrost the coil set to Fan Only mode Then set temperature to a higher setting UNIT WILL NO...

Страница 18: ...for Home Comfort Distributed by Perfect Aire LLC 5151 Belt Line Rd Suite 878 Dallas TX 75254 Specification and performance data is subject to change without notice Printed in PRC 877 365 6274 www per...

Отзывы: