-5-

OUTDOOR GRILLE

(SOLD SEPERATELY

)

An  outside  grille  must  be  installed  to  direct  air  flow  for 
proper unit operation and also protect the outdoor coil. The 
grille must be installed before installing the chassis.  
When replacing an old chassis with an existing grille or 

using  a  specialized  grille  in  a  new  installation,  please 
check with

 

supplier to determine if the  new  chassis 

should  be  used  with  the  nonstandard specialized grille. 

An improper outdoor grille can decrease cooling or 

heating capacity, increase energy usage and shorten 

compressor life and possibly void the warranty.

2. Insert the chassis into the wall sleeve.

Wall

 

Sleeve

Chassis

Flush

 

Stamped

 

Louver

Slide

 

Chassis

 

in

Outside

 

wall

Chassis

 

Installation

 

View

 

1

Architectural

 

Louver

Wall

 

Sleeve

Screws

CHASSIS INSTALLATION 

1.  Remove the cabinet front from the chassis as  described
below (1a and 1b).

(

3

 

on

 

each

 

side

 

of

 

unit

)

• 

Grasp the cabinet front.

Chassis

Outside

 

wall

Chassis

 

Installation

 

View

 

2

3.

 

Secure the chassis to the wall sleeve using three screws

on  each  side  of  the  chassis  to  ensure  a  proper  seal
between the chassis and the wall sleeve. The screws are
supplied in a plastic bag.

IMPORTANT NOTES: 

Cabinet

 

Front

 

Removal

 

View

 

1

• 

Pull the bottom of the cabinet front away from the

 

chassis until the retaining clips disengage.

Cabinet

 

Front

 

Removal

 

View

 

2

• Remove shipping tape from front panel as shown i

n

 

Figure 12 on page 8

• Remove shipping screw from vent door as shown i

n

 

Figure 13 on page 8. 

1. The unit is equipped with a rubber grommet mounted
compressor. These grommets are factory set and require
no adjustment.
2. Check the indoor and outdoor grilles for obstructions to
air flow.  The unit must be located where curtains, furniture,
trees, or other objects do not block the air flow to and from
the unit.  If air is obstructed and/or deflected back into the
unit, the air conditioner compressor may cycle on and off
rapidly.   This could damage the compressor or possibly
void the warranty.

• Slide the chassis into the wall sleeve until the chassis 

flanges contact the front edge of the wall sleeve.

Содержание 2PTC12A-3.0

Страница 1: ...MODELS 2PTC12A 3 0 2PTH15A 5 0 Before using your air conditioner please read this manual carefully and keep it for future reference along with your receipt USER MANUAL PACKAGED TERMINAL AIR CONDITION...

Страница 2: ...nt the right is reserved to change specifications and design without notice IMPORTANT NOTE TO THE OWNER This manual is to be used by qualified professionally trained HVAC technicians only The manufact...

Страница 3: ...ation Protection Automatically protects the compressor if heat pump is operated with high indoor coil temperatures Power to the outdoor fan and the compressor are turned off if the indoor coil gets to...

Страница 4: ...at Electric And Non Electric Sub Base Kit IR REMOTE CONTROLLER NOTE Consult sales literature for the appropriate voltage and amperage selections if applicable 3 R LS GH B Y W GL C WALL MOUNTED THERMOS...

Страница 5: ...ion of this unit is described in the following sections Following the steps in the order presented should ensure proper installation Front and discharge grille Electric heater Indoor Fan Display Modul...

Страница 6: ...assis Installation View 2 3 Secure the chassis to the wall sleeve using three screws on each side of the chassis to ensure a proper seal between the chassis and the wall sleeve The screws are supplied...

Страница 7: ...High fan speed Blue Reversing valve Yellow Compressor White Heater Orange Low fan speed Black Common ground RLSGHBYWGLC R LS GH B Y W GL C WALLMOUNTEDTHERMOSTATINTERFACE Thermostat WARNING TO AVOID TH...

Страница 8: ...ent time indicator TEMPsetting button This button is used to sent the room temperature Pressing of or button the temperature setting is increased or decreased FAN SPEED button Press this button to sel...

Страница 9: ...ODE button select the operation mode cool fan heat Press or button to set your desired temperature The setting temperature range is 61 88 F 16 31 C Press the FAN SPEED button to set your desired air f...

Страница 10: ...Front Back MAINTENANCE AND CLEANING AIR DISCHARGE GRILLE The discharge grille can be adjusted to expel air at either a 15 or 55 angle Discharge Grille Orientation Options 15 Discharge Air 55 Discharge...

Страница 11: ...lastic Creating this seal prevents water from entering the control area or the fan motor and damaging the unit 2 Spray condenser coil and base pan down with water Next spray a mild biodegradable deter...

Страница 12: ...outside of the unit Air sounds The fan cycle switch sets the operational mode of the fan In the ON position the fan will run continuously whenever power is applied in this mode In the AUTO position t...