SAFETY PRECAUTIONS

•  Do not use means to accelerate the defrosting process or to clean, other than those recommended by

the manufacturer.

•  The appliance should be stored in a room without continuously operating ignition sources 

(for example: open flames, an operating gas appliance or an operating electric heater).

•  Do not pierce or burn.
•  Be aware that the refrigerants do not have an odor. 
•  The appliance should be installed, operated and stored in a room with a floor area according to the

amount of refrigerant to be charged. For specific information on the type of gas and the amount, please 

refer to the relevant label on the unit itself.

•  Appliance should be installed, operated and stored in a room with a floor area larger than 4 m

2

.

Compliance with national gas regulations should be observed. Keep ventilation openings clear of 

obstruction.

•  The appliance should be stored so as to prevent mechanical damage from occurring.
•  A warning that the appliance should be stored in a well-ventilated area where the room size corresponds

to the room area as specified for operation.

•  Any person who is involved with working on or breaking into a refrigerant circuit should hold a current

valid certificate from an industry-accredited assessment authority, which authorizes their competence to 

handle refrigerants safely in accordance with an industry recognized assessment specification.

•  Servicing should only be performed as recommended by the equipment manufacturer. Maintenance and

repair requiring the assistance of other skilled personnel should be carried out under the supervision of 

the person competent in the use of flammable refrigerants.

•  The appliance should be stored in a room without continuously operating open flames (for example an

operating gas appliance) and ignition sources (for example an operating electric heater).

WARNING for Using R32/R290 Refrigerant

CAUTION: Risk of fire/flammable materials

Explanation of symbols displayed on the unit (For a unit with R32/R290 Refrigerant only):

WARNING

This symbol shows that this appliance used a flammable refrigerant. If the refrigerant is 

leaked and exposed to an external ignition source, there is a risk of fire.

CAUTION

This symbol shows that the operation manual should be read carefully.

CAUTION

This symbol shows that a service personnel should be handling this equipment with  

reference to the installation manual.

CAUTION

This symbol shows that information is available such as the operating manual or  

installation manual.

CONTINUED

6

Содержание 1PDP60

Страница 1: ...Dehumidifier OWNER S MANUAL INSTALLATION MANUAL 6 Model 1PDP60...

Страница 2: ...d Case Cleaning the Bucket Cleaning the Air Filter When Not in Use Longer Time Periods Troubleshooting Tips 3 12 12 13 14 14 15 17 18 21 21 21 21 22 IMPORTANT NOTE Read this manual carefully before in...

Страница 3: ...aust openings with cloths or towels Care should be taken when using the unit in a room with the following persons infants children elderly people and people sensitive to humidity Do not use in areas w...

Страница 4: ...appliance in a location that may be exposed to combustible gas If combustible gas accumulates around the unit it may cause fire If the appliance is knocked over during use turn off the unit and unplug...

Страница 5: ...cable to a unit using R290 Refrigerant CONTINUED Ensure the unit is properly grounded To minimize shock and fire hazards proper grounding is important The power cord is equipped with a three pronged g...

Страница 6: ...ircuit should hold a current valid certificate from an industry accredited assessment authority which authorizes their competence to handle refrigerants safely in accordance with an industry recognize...

Страница 7: ...resence of refrigerant The area should be checked with an appropriate refrigerant detector prior to and during work to ensure the technician is aware of potentially flammable materials Ensure that the...

Страница 8: ...be corrected immediately but it is necessary to continue operation an adequate temporary solution should be used This should be reported to the owner of the equipment so all parties are advised Initi...

Страница 9: ...the use of detergents containing chlorine should be avoided as the chlorine may react with the refrigerant and corrode the copper pipework If a leak is suspected all naked flames should be removed ex...

Страница 10: ...with the equipment and it s operation b Isolate the system electrically c Before attempting the procedure ensure that i Mechanical handling equipment is available if required for handling refrigerant...

Страница 11: ...erants In addition a set of calibrated weighing scales should be available and in good working order Hoses should be complete with leak free disconnect couplings and in good condition Before using the...

Страница 12: ...th sides Control panel Water level window Water bucket Air Filter Continuous drain hose outlet Power cord buckle placed in the water bucket used only when storing the unit Air outlet grille Pump drain...

Страница 13: ...ooth level floor strong enough to support the unit with a full bucket of water Allow at least 8 of air space on all sides of the unit for good air circulation at least 16 of air space on air outlet Pl...

Страница 14: ...socket outlet which is also being used for other electrical appliances Select a suitable location making sure you have easy access to an electrical outlet Plug the unit into an electrical socket outl...

Страница 15: ...fan speed Set the fan control to High for maximum moisture removal When the humidity has been reduced and quiet operation is preferred set the fan control to Normal Press to turn the dehumidifier on a...

Страница 16: ...he unit with pump feature Eb Bucket is removed or not in right position Replace the bucket in the right position Only available for the unit with pump feature Press to activate the comfort dehumidifyi...

Страница 17: ...power resumes When the unit is on first press the Timer button the Timer Off indicator light illuminates It indicates the Auto Stop program is initiated Press it again the Timer On indicator light il...

Страница 18: ...hrow away the water and replace the bucket The bucket must be in right place and securely installed for the dehumidifier to operate The machine will re start when the bucket is restored in its correct...

Страница 19: ...oward the drain making sure that there are no kinks that will stop the water flowing Make sure the water hose is lower than the drain hose outlet of the unit Select the desired humidity setting and fa...

Страница 20: ...make sure the end of the hose is level or down to let the water flow smoothly Select the desired humidity setting and fan speed on the unit for pump draining to start Please turn off the unit and dis...

Страница 21: ...tic bag Store the unit upright in a dry well ventilated place Every few weeks clean the bucket to prevent growth of mold mildew and bacteria Partially fill the bucket with clean water and add a little...

Страница 22: ...ther openings are securely closed Room temperature is too low below 41 F There is a kerosene heater or something giving off water vapor in the room The unit makes a loud noise when operating The air f...

Страница 23: ...s are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the service website please...

Страница 24: ...844 4PA AIRE 844 472 2473 www perfectaire us 1020_M516 Perfect Aire LLC 5401 Dansher Road Countryside IL 60625 Printed in China...

Отзывы: