background image

OPERATING INSTRUCTIONS

•  Check that the pump drain hose does not link 

or back.

•  Empty the water of the bucket.
•  Reinstall the pump hose if it drops and reinstall 

the bucket properly. Turn on the unit. If the error 

repeats, call for service.

•  Water can be automatically emptied into a fl oor

drain or a suitable drainage facility by attaching 

the pump drain outlet with a pump drain hose  

(included).

•  Remove the continuous drain hose from the unit

and install the plastic cover to the continuous 

drain hose outlet of the unit by clockwise rotation.

•  Reinsert the pump drain hose into the pump drain

hose outlet for depth of 15mm at least, then lead 

the water hose to the fl oor drain or a suitable 

drainage facility.

3. Pump Draining (on some models)

•  Press the pump pad of the unit to activate the

pump operation. When the bucket is full, the pump 

starts to work.

•  Make sure the hose is secure so there are 

no leaks.

•  Direct the hose toward the drain, making sure that

there are no kinks that will stop the water fl owing.

•  Place the end of the hose into the drain and make

sure the end of the hose is level or down to let the 

water fl ow smoothly.

•  Select the desired humidity setting and fan speed

on the unit for pump draining to start.

Please turn off  the unit and disconnect the power 

cord out. Check the following things:
• Cleaning the fi lter of the pump.
• Remove the bucket from the unit, take down the

pump and clean the fi lter of the pump.

Note

Note

The pump may cause a loud noise when it 

starts to work for 3~5 minutes. It is a normal 

phenomenon. 

Do not use this operation when the outdoor 

temperature is equal to or less than 32 °F, 

otherwise water is become ice that will cause the

water hose blocked up and the unit failure. 

Make sure to empty the bucket once a week 

when using the pump draining feature. When the 

pump draining feature is not being used, remove 

the pump drain hose from the outlet. Press the 

pump drain hose outlet in and take the pump 

drain hose out from it. Make sure do not let the 

water in the pump hose drip to the fl oor.

Note

The pump operation “on” light blinks at 1Hz 

when the pump is having an operational failure. 

Reinstall the 

plastic cover

Pump drain hose

Pump drain hose outlet

Filter of the pump

1. Press the pump drain hose outet in

2. Take the pump drain hose out

2

1

CONTINUED

20

Содержание 1PDP60

Страница 1: ...Dehumidifier OWNER S MANUAL INSTALLATION MANUAL 6 Model 1PDP60...

Страница 2: ...d Case Cleaning the Bucket Cleaning the Air Filter When Not in Use Longer Time Periods Troubleshooting Tips 3 12 12 13 14 14 15 17 18 21 21 21 21 22 IMPORTANT NOTE Read this manual carefully before in...

Страница 3: ...aust openings with cloths or towels Care should be taken when using the unit in a room with the following persons infants children elderly people and people sensitive to humidity Do not use in areas w...

Страница 4: ...appliance in a location that may be exposed to combustible gas If combustible gas accumulates around the unit it may cause fire If the appliance is knocked over during use turn off the unit and unplug...

Страница 5: ...cable to a unit using R290 Refrigerant CONTINUED Ensure the unit is properly grounded To minimize shock and fire hazards proper grounding is important The power cord is equipped with a three pronged g...

Страница 6: ...ircuit should hold a current valid certificate from an industry accredited assessment authority which authorizes their competence to handle refrigerants safely in accordance with an industry recognize...

Страница 7: ...resence of refrigerant The area should be checked with an appropriate refrigerant detector prior to and during work to ensure the technician is aware of potentially flammable materials Ensure that the...

Страница 8: ...be corrected immediately but it is necessary to continue operation an adequate temporary solution should be used This should be reported to the owner of the equipment so all parties are advised Initi...

Страница 9: ...the use of detergents containing chlorine should be avoided as the chlorine may react with the refrigerant and corrode the copper pipework If a leak is suspected all naked flames should be removed ex...

Страница 10: ...with the equipment and it s operation b Isolate the system electrically c Before attempting the procedure ensure that i Mechanical handling equipment is available if required for handling refrigerant...

Страница 11: ...erants In addition a set of calibrated weighing scales should be available and in good working order Hoses should be complete with leak free disconnect couplings and in good condition Before using the...

Страница 12: ...th sides Control panel Water level window Water bucket Air Filter Continuous drain hose outlet Power cord buckle placed in the water bucket used only when storing the unit Air outlet grille Pump drain...

Страница 13: ...ooth level floor strong enough to support the unit with a full bucket of water Allow at least 8 of air space on all sides of the unit for good air circulation at least 16 of air space on air outlet Pl...

Страница 14: ...socket outlet which is also being used for other electrical appliances Select a suitable location making sure you have easy access to an electrical outlet Plug the unit into an electrical socket outl...

Страница 15: ...fan speed Set the fan control to High for maximum moisture removal When the humidity has been reduced and quiet operation is preferred set the fan control to Normal Press to turn the dehumidifier on a...

Страница 16: ...he unit with pump feature Eb Bucket is removed or not in right position Replace the bucket in the right position Only available for the unit with pump feature Press to activate the comfort dehumidifyi...

Страница 17: ...power resumes When the unit is on first press the Timer button the Timer Off indicator light illuminates It indicates the Auto Stop program is initiated Press it again the Timer On indicator light il...

Страница 18: ...hrow away the water and replace the bucket The bucket must be in right place and securely installed for the dehumidifier to operate The machine will re start when the bucket is restored in its correct...

Страница 19: ...oward the drain making sure that there are no kinks that will stop the water flowing Make sure the water hose is lower than the drain hose outlet of the unit Select the desired humidity setting and fa...

Страница 20: ...make sure the end of the hose is level or down to let the water flow smoothly Select the desired humidity setting and fan speed on the unit for pump draining to start Please turn off the unit and dis...

Страница 21: ...tic bag Store the unit upright in a dry well ventilated place Every few weeks clean the bucket to prevent growth of mold mildew and bacteria Partially fill the bucket with clean water and add a little...

Страница 22: ...ther openings are securely closed Room temperature is too low below 41 F There is a kerosene heater or something giving off water vapor in the room The unit makes a loud noise when operating The air f...

Страница 23: ...s are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the service website please...

Страница 24: ...844 4PA AIRE 844 472 2473 www perfectaire us 1020_M516 Perfect Aire LLC 5401 Dansher Road Countryside IL 60625 Printed in China...

Отзывы: