OPERATING INSTRUCTIONS
CONTINUED
OTHER FEATURES
Glows when the bucket is ready to be emptied.
When frost builds up on the evaporator coils, the
compressor will cycle off and the fan will continue to
run until the frost disappears.
The dehumidifier shuts off when the bucket is full,
or when the bucket is removed or not replaced
in the proper position. For some models, the fan
motor will continue to run for 30 seconds. Wait 3
minutes before resuming operation. After the unit
has stopped, it cannot restart operation in the first
3 minutes. This is to protect the unit. Operation will
automatically start after 3 minutes.
The system starts to count the time once the fan
motor operates. The check filter feature can be
only activated when the accumulated operation time
achieves 250 hours or more. The Reset light
(Clean filter indicator light) flashes once per second,
after finishing cleaning the air filter, press the Filter
button and the Reset light (Clean filter indicator light)
goes off.
If the unit breaks off unexpectedly due to the power
cut, it will restart with the previous function setting
automatically when the power resumes.
• When the unit is on, first press the Timer button,
the Timer Off indicator light illuminates. It indicates
the Auto Stop program is initiated. Press it again
the Timer On indicator light illuminates. It indicates
the Auto Start is initiated.
• When the unit is off, first press the Timer button,
the Timer On indicator light illuminates. It indicates
the Auto Start program is initiated. Press it again
the Timer Off indicator light illuminates. It indicates
the Auto Stop is initiated.
• Press or hold the UP or DOWN button to change
the Auto time by 0.5-hour increments, up to 10
hours, then at 1 hour increments up to 24 hours.
The control will count down the time remaining
until start.
• The selected time will register in 5 seconds and
the system will automatically revert back to display
the previous humidity setting.
• When the Auto Start & Auto Stop times are set,
within the same program sequence, Timer On/Off
indicator lights illuminate identifying both On and
Off times are now programmed.
• Turning the unit On or Off at any time or adjusting
the timer setting to 0.0 will cancel the Auto Start/
Stop function.
• When LED display window displays the code
of P2, the Auto Start/Stop function will also
be cancelled.
BUCKET FULL LIGHT
AUTO DEFROST
AUTO SHUT OFF
CHECK FILTER FEATURE
AUTO-RESTART
SETTING THE TIMER