12
7. Dripping water may generate on the surface of the indoor unit when cooling in a high
relative humidity (relative humidity higher than 80%). Adjust the horizontal louver to
the maximum air outlet position and select HIGH fan speed.
8. Heating mode (For cooling and heating models only)
The air conditioner draws in heat from the outdoor unit and releases it via the indoor unit
during heating operation. When the outdoor temperature falls, heat drawn in by the air
conditioner decreases accordingly. At the same time, heat loading of the air conditioner
increases due to larger difference between indoor and outdoor temperature. If a
comfortable temperature can't be achieved by the unit, we suggest you use a
supplemental heating device.
9. Auto-restart function
Power failure during operation will stop the unit completely.
For the unit without Auto-restart feature, when the power restores, the “OPERATION” indicator
on the indoor unit starts flashing. To restart the operation, push the “ON/OFF” button on the
remote control. For the unit with Auto-restart feature, when the power restores, the unit
restarts automatically with all the previous settings preserved by the memory function.
For some models, the unit is designed with Auto-restart function for the open angle
of the horizontal louver. Power failure during operation or pressing the “ON/OFF” button on the
remote control will stop the unit completely. When the power restores or pressing the “ON/OFF”
button on the remote control again, the unit restarts automatically with all the previous settings
including the open angle of the horizontal louver by the memory function. So we strongly suggest
that the open angle of the horizontal louver should not be set too small, in case the condensed
water forms and drops from the horizontal louver. Press the “AUTO/COOL” button under the
front panel and the open angle of the horizontal louver will be restored to the standard angle
when the condensed water forms on the horizontal louver.
10. Lightning or a wireless telephone operating nearby may cause the unit to malfunction.
Disconnect the unit from the power and then re-connect the unit with power again. Push the
“ON/OFF” button on the remote control to restart operation.
11. The protection of outdoor low temperature (on some models)
The protection of outdoor low temperature can be activated only in the HEATING mode.
The unit will stop operating and display "P3" on the LCD window of the indoor unit when the
outdoor temperature is or lower than
for one hour, but the indoor unit in this situation
can still receive the signal from the remote control. The unit will restart automatically with all the
previous settings preserved by the memory function when the outdoor temperature is higher
than
for 10 minutes and the compressor stops operating for more than one hour, or
when the outdoor temperature is or higher than
for 10 minutes.
OPERATION TIPS
5ºF(-15ºC)
11ºF(-12ºC)
41ºF(5ºC)