OPERATION TIPS

The following events may occur during normal operation.
1. Protection of the air conditioner.

Compressor protection
The compressor can't restart for 3 minutes after it stops.
Anti-cold air (Cooling and heating models only)
The unit is designed not to blow cold air in HEAT mode, when the indoor heat exchanger is in
one of the following three situations and the set temperature has not been reached.

A) When heating has just started.

B) Defrosting is occurring.
C) Low temperature heating is occurring.
The indoor or outdoor fan stop running when defrosting (Cooling and heating models only).
Defrosting (Cooling and heating models only)
Frost may be generated on the outdoor unit during heat cycle when outdoor temperature is low
and humidity is high resulting in lower heating efficiency of the air conditioner.
During this condition air conditioner will stop heating operation and start defrosting automatically.
The time to defrost may vary from 4 to 10 minutes according to the outdoor temperature and

the amount of frost build up on the outdoor unit.

2. A white mist coming out from the indoor unit

A white mist may generate due to a large temperature difference between air inlet and air outlet

in COOL mode with an indoor environment that has a high relative humidity.

A white mist may be generated due to moisture generated from defrosting process. When the air

conditioner restarts in HEAT mode operation after defrosting.

3. Low noise of the air conditioner

You may hear a low hissing sound when the compressor is running or has just stoped running.
This sound is the sound of the refrigerant flowing or coming to a stop.
You can also hear a low "squeak" sound when the compressor is running or has just stopped
running. This is caused by heat expansion and cold contraction of the plastic parts in the unit
when the temperature is changing.

A noise may be heard due to louver restoring to its original position when power is first turned on.

4. Dust is blown out from the indoor unit.

This is a normal condition when the air conditioner has not been used for a long time or during first
use of the unit.

5. A peculiar smell comes out from the indoor unit.

This is caused by the indoor unit giving off smells permeated from building material, from furniture,
or smoke.

6. The air conditioner turns to “FAN” only mode from “COOL” or “HEAT” (For cooling and

heating models only) mode.

When indoor temperature reaches the temperature setting on air conditioner, the compressor will
stop automatically ,and the air conditioner turns to “FAN” only mode. The compressor will start again
when the indoor temperature rises on “COOL” mode or falls on “HEAT” mode (For cooling and heating
models only) to the set point.

Содержание 1PAMSH30-SZO-14.5

Страница 1: ...YPE AIR CONDITIONER This manual provides the information needed for proper use and maintenance of this air conditioner Basic preventive care can help extend the life of this unit The Troubleshooting T...

Страница 2: ...nce of this unit Contact the installer for installation of this unit This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack o...

Страница 3: ...e due to heat generation It may cause electric shock It may cause failure of machine or electric shock It contains contaminants and could make you sick This could cause health issues No installation m...

Страница 4: ...shortage may occur Do not use this air cond itioner to preserve preci sion devices food pets plants and art objects It may cause deterioration of quality etc Not doing this may cause failure of produc...

Страница 5: ...nel 6 Horizontal louver 7 Vertical louver on some models 8 Air lter under the panel 9 Manual control button 10 Remote control holder 11 Remote control 12 Connecting pipe 13 Drain hose 14 Connecting ca...

Страница 6: ...indicator For Cooling Heating models only This indicator illuminates when the air conditioner starts defrosting automatically or when the warm air control feature is activated in heating operation TEM...

Страница 7: ...emote control directly CAUTION 1 3 2 NOTE The unit must be turned off before operating the manual control button If the unit is operational continue pressing the manual control button until the unit i...

Страница 8: ...the vertical louver can be adjusted by using the remote control Please refer to the REMOTE CONTROL OPERATION MANUAL for details Do not operate the air conditioner for long periods with the air ow dire...

Страница 9: ...ff This characteristic maintains both energy saving and comfort in night operation DRYING operation The fan speed will be automatically controlled under dry operation During the dry operation if the r...

Страница 10: ...e and maintenance Turn the system off before cleaning To clean wipe with a soft dry cloth Do not use bleach or abrasives NOTE Supply power must be disconnectd before cleaning the indoor unit Filter Ha...

Страница 11: ...water can destroy the insulation leading to possible electric shock When cleaning the unit rst make sure that the power and circuit breaker are turned off Caution Air freshening lter Air freshening l...

Страница 12: ...t that has a high relative humidity A white mist may be generated due to moisture generated from defrosting process When the air conditioner restarts in HEAT mode operation after defrosting 3 Low nois...

Страница 13: ...control will stop the unit completely When the power restores or pressing the ON OFF button on the remote control again the unit restarts automatically with all the previous settings including the op...

Страница 14: ...ly 3 minutes for compressor to turn on and the unit to begin cooling heating Inappropriate temperature setting Air lter is blocked Doors or windows are open Air inlet or outlet of indoor or outdoor un...

Страница 15: ......

Страница 16: ...2020331A2042...

Отзывы: