TTR-04CW Electromechanical Tripod Turnstile
Figure 7. ACS control element — normally open relay contact
Figure 8. ACS control element — circuit with open-collector output
Figure 9. Output cascades for PASS A, PASS B, Ready, Det Out and Alarm
5.5 Control modes
5.5.1 There are two modes of the turnstile control -
a pulse control mode and a potential
control mode
. They determine available
operating modes
of the turnstile
(Table 2 and
Table 3).
5.5.2 The control mode is set by the jumper on the J1 connector (the J1 connector location
is shown on Fig. 5 and on a label located on the inner surface of turnstile cover (2): the
jumper is fixed — the pulse control mode, the jumper is not fixed – the potential control
mode. The jumper is fixed at the factory before the delivery.
13
Содержание TTR-04CW
Страница 1: ...ASSEMBLY AND OPERATION MANUAL TTR 04CW Electromechanical Tripod Turnstile...
Страница 2: ...Electromechanical Tripod Turnstile TTR 04CW Assembly and Operation Manual...
Страница 11: ...Assembly and Operation Manual Figure 6 Connection layout 10...
Страница 31: ......
Страница 32: ......
Страница 34: ...www perco com...