Assembly and Operation Manual
Note:
Pressing the button on the RC panel corresponds to the low-level signal supply to
the contacts (
Unlock A, Unlock B
and
Stop
) of the
XT1.L
connector block relatively to
the contact
GND
.
9.3 Turnstile operating modes in potential control mode
See Table 3 for the operating modes set from the RC panel. Setting the operating modes
for each direction is independent, i.e. setting the operating mode for one direction does not
change the operating mode set earlier for the opposite one.
Note. For the ACS outputs note the following:
High level — contacts of the output relay are broken or the output transistor is
closed;
Low level — contacts of the output relay are closed or the output transistor is open
Table 3 Potential control mode (the jumper is taken off from the J1 connector)
№
The
turnstile
operating
modes
Levels
on the
contacts
should
be provided
Indication
on the RC
panel
Indication
on the led
display
Turnstile status
1
Both directions
are locked
(the turnstile
is locked both
for entry
and exit)
The high level —
on contacts
“Unlock A”
and “Unlock B”
or low level —
on the contact Stop
The
red indicator
above
the
STOP
button
is on
The
“Red cross”
pictogram
is on
The turnstile is locked
2
One
of the passage
directions
is open
(the turnstile
is open
for passage
in the set
direction)
The low level —
on the contact
corresponding
to the passage
direction,
the high levels —
on the other
contacts
The
green indicator
above
the button
of the chosen
passage direction
is on
The
“Green arrow”
pictogram,
showing
the passage
direction is on
If by the moment
of passage through
the turnstile the low
level is present
on the contact,
corresponding
to the set passage
direction, the turnstile
remains open
in the set direction
3
Both passage
directions
are open
(the turnstile
is open
for passage
in both
directions)
The low levels —
are on the contacts
corresponding
to the both
directions,
the high level —
on the contact Stop
The two green
indicators
(left and right) are
on
The two
“Green arrow”
pictograms
(left and right)
are on
If by the moment
of passage through
the turnstile the low
level is present
on the contact,
corresponding
to the set passage
direction, the turnstile
remains open
in the set direction
24
Содержание TTR-04CW
Страница 1: ...ASSEMBLY AND OPERATION MANUAL TTR 04CW Electromechanical Tripod Turnstile...
Страница 2: ...Electromechanical Tripod Turnstile TTR 04CW Assembly and Operation Manual...
Страница 11: ...Assembly and Operation Manual Figure 6 Connection layout 10...
Страница 31: ......
Страница 32: ......
Страница 34: ...www perco com...