9.5 Troubleshooting
Possible faults, which can be cleared by the users themselves, are listed in Table 7.
Table 7 – Possible faults and remedy
Fault
Possible cause
Remedy
At the power-up the
turnstile doesn’t work,
and there is no light
indication on the
turnstile housing and the
RC panel
No supply voltage
to the CLB
Switch off the turnstile power supply from the AC
mains, open the turnstile housing cover. Check the
power cable serviceability and reliability of its
connection to the CLB
XS1
and
XT3
connector
blocks
The turnstile is not
controlled in one of the
directions, and there is
light indication on the
turnstile housing and on
the RC panel
The CLB does not
receive a control
signal for this
direction
Switch off the turnstile power supply from the AC
mains, open the turnstile housing cover, and remove
the outer panel. Check the RC panel / WRC kit / ACS
controller cable serviceability and reliability of its
connection to the CLB
XS1
connector block
In case of other faults and defects, please apply to the PERCo Technical Support
Department (the PERCo TSD).