Operation manual
26
Appendix
А
Control signal algorithm at pulse control mode
Note! For the RC-panel:
•
active front — pressing of the relevant button on the RC-panel;
•
low level — the relevant button on the RC-panel has been pressed;
•
high level — the relevant button on the RC-panel has not been pressed.
The following commands can be formed by sending a low-level signal to the contacts “Unlock A”,
“Stop” and “Unlock B” of the “XT1.L” connector block relatively to the contact “GND” (The
command is a signal active front (signal transfer from the high level to the low level) at any of the
contacts at presence of the corresponding signal levels at the other contacts):
Always locked (closed for entry and exit) -
Active front is at contact “Stop” while there is a high level at contacts “Unlock A” and “Unlock B”.
Both passage directions get closed at this command.
Single passage in direction А (open for passage of one person in direction А)
-
Active front is at contact “Unlock A” while there is a high level at contacts “Stop” and “Unlock B”.
At this command passage direction А opens either for 5 sec. or until the passage has been made
in this direction or until the command
«Always locked»
, and the status of passage direction В
does not change. The command is ignored if at the moment of its receipt the status of passage
direction А was
«Always free»
.
Single passage in direction В (open for passage of one person in direction В)
-
Active front is at contact “Unlock B” while there is a high level at contacts “Stop” and “Unlock A”.
At this command passage direction B opens either for 5 sec. or until the passage has been
effected in this direction or until the command
«Always
locked»
, and the status of passage
direction A does not change. The command is ignored if at the moment of its receipt the status of
passage direction B was
«Always free»
.
Single passage in both directions (open for single passage of one person at a time in each
direction) -
Active front is at contact “Unlock A” while there is a low level at contact “Unlock B” and a high level
at contact “Stop”,
or active front is at contact “Unlock B” while there is a low level at contact “Unlock A” and a high
level at contact “Stop”.
At this command the both passage directions open either for 5 sec. each or until the command
«Always locked»
is received. The command is ignored for the passage direction, which status at
the moment of its receipt was
«Always free»
.
Free passage in direct
ion А (open for free passage in direction А)
-
Active front is at contact “Unlock A” while there is a low level at contact “Stop” and a high level at
contact “Unlock B”,
or active front is at contact “Stop” while there is a low level at contact “Unlock A” and a high level at
contact “Unlock B”.
At this command passage direction А opens until the command
«Always locked»
is received and
the status of passage direction В does not change.
Free passage in direction В (open for free passage in direction В)
-
Active front is at contact “Unlock B” while there is a low level at contact “Stop” and a high level at
contact “Unlock A”,
or active front at contact “Stop” while there is a low level at contact “Unlock B” and a high level at
contact “Unlock A”.
At this comman
d passage direction В opens until the command
«Always locked»
is received and
the status of passage direction А does not change.
Free passage (open for passage in both directions) -
Active front is at contact “Unlock A” while there is a low level at contacts “Unlock B” and “Stop”,
or active front is at contact “Unlock B” while there is a low level at contacts “Unlock A” and “Stop”,
or active front is at contact “Stop” while there is a low level at contacts “Unlock A” and “Unlock B”.
The both directions open at this command until the command
«Always locked»
is received.
Содержание TTD-03.1
Страница 1: ...OPERATION MANUAL TTD 03 1 Electromechanical Box Tripod Turnstile...
Страница 2: ...Electromechanical Box Tripod Turnstile TTD 03 1 Operation Manual...
Страница 20: ...TTD 03 1 Electromechanical Box Tripod Turnstile 19 8 1 Connection layout Fig 13 Connection layout...
Страница 30: ...www perco com...