TTD-03.1 Electromechanical Box Tripod Turnstile 

23 

 

Fig. 14 Anti-panic drop arms application 

When using the standard barrier arms, it is possible to provide free passage through the turnstile 

by unblocking it with the mechanical release key. The sequence of actions is described in Clause 

5.10. 

9.5  Mechanical unblocking of the turnstile 

Possibility to unblock the turnstile manually is specially provided for unblocking of the turnstile in 

the emergency mode at the power supply failure.  
To unblock the turnstile it is necessary to insert the key into the mechanical release lock 

 

(8) and 

turn it clockwise up to the stop

 

(the lock cylinder moves out of the case). The barrier arms can be 

freely turned in both directions 
Deactivating mechanical unblocking of the turnstile in the following order: 

  install barrier arms to the starting position; 

  click on the lock mechanism mechanical release, sinking it into the housing until it clicks; 

  make sure that the turnstile is locked, and the barrier arms do not rotate in any direction. 

9.6  Troubleshooting 

Possible faults, which can be cleared by the users themselves, are listed in Table 5. 

Table 4 Possible faults and remedy 

Fault  

Possible 

cause 

Remedy  

At the power-up the 

turnstile won’t work, and 

there is no light indication 

on the turnstile housing and 

the RC-panel.  

No supply 

voltage to the 

CLB  

Switch off the turnstile power supply from the AC 

mains, open the turnstile housing cover, and 

remove the outer panel. Check the power cable 

serviceability and reliability of its connection to the 

CLB “XT3” connector block  

The turnstile is not 

controlled in one of the 

directions, and there is light 

indication on the turnstile 

housing and on the RC-

panel.  

The CLB does 

not receive a 

control signal 

from this 

direction 

Switch off the turnstile power supply from the AC 

mains, open the turnstile housing cover, and 

remove the outer panel. Check the RC-panel / 

WRC kit / ACS controller cable serviceability and 

reliability of its connection to the CLB “XT1.L” and 

“XT1.H” connector blocks  

Other possible faults shall be eliminated by representatives of the manufacturer. 

10  MAINTENANCE 

The turnstile maintenance is required once a year or in case of some technical failures. The 

maintenance should be only carried out by qualified mechanic. Prior to the turnstile maintenance 

procedure disconnect the turnstile power supply from AC mains. 
Remove the turnstile cover (3) following the below: 

Содержание TTD-03.1

Страница 1: ...OPERATION MANUAL TTD 03 1 Electromechanical Box Tripod Turnstile...

Страница 2: ...Electromechanical Box Tripod Turnstile TTD 03 1 Operation Manual...

Страница 3: ...ices connectable to the turnstile 12 5 5 Operation contingencies and response 13 6 MARKING AND PACKAGING 13 7 SAFETY REQUIREMENTS 14 7 1 Installation safety requirements 14 7 2 Operation safety requir...

Страница 4: ...ion into the product is carried out by the customer installer in accordance with the design of the pass through and the characteristics of the access control system and the control controller Access c...

Страница 5: ...ools Self adhesive wires retainer 2 Fixed brace rod 100 mm 2 Operational documentation Certificate 1 Operation manual 1 Packaging Box 1 for turnstile housing 1 Box 2 for turnstile housing cover 1 4 2...

Страница 6: ...indicators application not more than 42 V The turnstile has low power consumption not more than 8 5 W The turnstile has galvanic decoupling of outputs Several lined up turnstiles form passageways with...

Страница 7: ...sktop device with a shock proof ABS plastic case and is intended for setting and indicating operating modes when the turnstile is operated manually The RC panel overall view is shown in Fig 3 There ar...

Страница 8: ...nnects to RC panel ACS controller outputs WRC device intrusion detector emergency unlocking device Fire Alarm External devices are connected in accordance with the turnstile electrical connection layo...

Страница 9: ...arm and relays the signal of the current status of the intruder detector Det Out The turnstile is operated by input of a low level signal to the XT1 L connector block contacts Unlock A Unlock B and St...

Страница 10: ...l Box Tripod Turnstile 9 Fig 5 Control elements of an external device a normally open relay contact Fig 6 ACS control element circuit with open collector output Fig 7 Output cascades for PASS A PASS B...

Страница 11: ...the duration of controlling signal The pulse control mode is intended for the turnstile control with the RC panel WRC and ACS controller outputs of which support the pulse control mode Standard contro...

Страница 12: ...he left side outer panel 2 see Fig 4 5 3 1 Operation with the RC panel When the buttons on the RC panel are pressed the STOP button and the two other buttons corresponding to the passage directions co...

Страница 13: ...ctor Note Only the manufacturer should carry out the installation of the intrusion detector on the turnstile housing If the turnstile is blocked Always locked mode or Both directions closed one see Ta...

Страница 14: ...the barrier arms reset into initial state the both optical sensors become normalized and the output contacts Ready and Common get closed finish of the signal In case of delay of an authorized passage...

Страница 15: ...nstile under conditions that do not comply with the requirements of Chapter 2 of this Manual Do not use the turnstile at supply voltage that does not comply with the requirements of Chapter 3 of this...

Страница 16: ...measurement accuracy 8 3 Cable length The maximum allowed length of the RC panel WRC ACS controller cable is not more than 50m The maximum allowed length of the turnstile power supply cable depends on...

Страница 17: ...nector block 10 If the turnstile is used in the potential mode remove the jumper from the J1 connector see Fig 4 11 Check serviceability and accuracy of all the electrical connections Fasten all the c...

Страница 18: ...indication cable 5 CLB 6 control mechanism 7 intrusion detector 8 siren 4 6 9 11 see Fig 13 14 Control the turnstile housing and barrier arms fastening check serviceability and accuracy of all the ele...

Страница 19: ...by the customer installer in accordance with the design of the pass through and the characteristics of the access control system and the control controller Access cards readers of are not included in...

Страница 20: ...TTD 03 1 Electromechanical Box Tripod Turnstile 19 8 1 Connection layout Fig 13 Connection layout...

Страница 21: ...rms turnstile housing and indication modules so as to prevent their mechanical deformation 9 1 Power up 1 Make sure of the accuracy of all the connections and of the power supply cable operability see...

Страница 22: ...to the chosen passage direction simultaneously The green indicator above the button of the chosen passage direction is on The Green arrow pictogram showing the passage direction and the Red cross pict...

Страница 23: ...hosen passage direction is on The Green arrow pictogram showing the passage direction and the Red cross pictogram from the opposite side are on If by the moment of passing through the turnstile the lo...

Страница 24: ...are listed in Table 5 Table 4 Possible faults and remedy Fault Possible cause Remedy At the power up the turnstile won t work and there is no light indication on the turnstile housing and the RC pane...

Страница 25: ...bricate the friction units of the resetting device with the machine oil four bushes of the resetting device two on the rotation axis of the pusher two on the fastening axis of the springs see Fig 15 h...

Страница 26: ...vered by means of transportation with covering facilities railroad cars covered truck car bodies vessel holds and by air transport It is not allowed to stockpile the boxes with the turnstile housings...

Страница 27: ...f its receipt the status of passage direction B was Always free Single passage in both directions open for single passage of one person at a time in each direction Active front is at contact Unlock A...

Страница 28: ...s open open for passage in direction There is a low level at contact Unlock while there is a high level at contacts Stop and Unlock At this command direction B opens up to the elimination of low level...

Страница 29: ...PERCo Polytechnicheskaya str 4 block 2 194021 Saint Petersburg Russia Tel 7 812 247 04 64 E mail export perco com support perco com www perco com...

Страница 30: ...www perco com...

Отзывы: