For installers and professionals
- 14 -
1.
Wiring diagram
Must be hard wired, no plug allowed.
For your safe use in winter, it’s strongly recommended to equip heating priority function.
For the detailed wiring diagram, please refer to Appendix 1.
2
.
Options for protecting devices and cable specification
MODEL
7301269 7301270 7301271 7301272
Breaker
Rated Current A
15.0
19.0
22.5
25.5
Rated Residual
Action Current mA
30
30
30
30
Fuse A
15.0
19.0
22.5
25.5
Power Cord
(
mm
2
)
3×2.5
3×4
3×4
3×6
Signal cable
(
mm
2
)
3×0.5
3×0.5
3×0.5
3×0.5
NOTE: The above data is adapted to power cord ≤ 10m. If power cord is
>
10m, wire diameter must be
increased. The signal cable can be extended to 50m at most.
2.3. Trial after installation
Please check all the wirings carefully before turning on the heat pump.
2.3.1
.
Inspection before use
Check installation of the whole heat pump and the pipe connections according to the pipe
connecting drawing;
Check the electric wiring according to the electrical wiring diagram and earthing
connection;
Make sure that the main power is well connected;
Check if there is any obstacle in front of the air inlet and outlet of the heat pump
2.3.2
.
Trial
The user is advised to start the water pump before the heat pump, and turn off the heat
pump before the water pump for long life circle.
The user should start the water pump, and check for any leakage of water; Power on and
press the ON/OFF button of the heat pump, and set desired temperature in the
thermostat.
In order to protect the heat pump, the heat pump is equipped with start delay
A. For power supply: 230V 50Hz
Distribution Box (Customer prepare)
Power Cord
Swimming Pool Heat Pump Wiring Board
Power Supply
230V 50Hz
Breaker
Earthing
Fuse
Содержание 7301269
Страница 1: ...DE EN ...
Страница 20: ...Für Monteure und Händler 18 Anhang 1 Schaltplan für Heizprioritätsfunktion Optional ...
Страница 21: ...Für Monteure und Händler 19 Anhang 2 Schaltplan für Heizprioritätsfunktion Optional ...
Страница 29: ...DE EN ...
Страница 47: ...For installers and professionals 17 Appendix 1 Heating priority wiring diagram Optional ...
Страница 48: ...For installers and professionals 18 Appendix 2 Heating priority wiring diagram Optional ...
Страница 56: ...Version E67XVr32 ...