An anti-disturbance hardware filter is implemented on the External Trigger input
An additional 15 ms (typical) delay can be implemented through a dedicated software
parameter (refer to VisoSetup Help On Line).
6.2.5
Outputs
Two general purpose outputs are available. These outputs can only be connected as
open collector configurations. The following pins are present on the 25-pin connector
of the scanner:
Figure 6.16
Output connections
Electrical features:
Maximum voltage:40 V DC
Maximum current:40 mA continuous
The meaning of the two outputs OUT1 and OUT2 can be defined by the user. Refer
to the VisoSetup Help On Line.
By default, OUT1 is associated with the No Read event, which activates when the
code signaled by the external trigger is not decoded, and OUT2 is associated with the
Right event, which activates when the code is correctly decoded.
These outputs are both level or pulse configurable.
Connector
25-pin
Name
Function
8
OUT1+
output 1 +
11
OUT2+
output 2 +
12, 22
OUT REF
output reference
USER
INTERFACE
VB14A 25-pin
40 V DC max.
Vext
OUT 1+ / OUT 2+
OUT REF
8/11
12/22