Product Description
Figure 2.14
The direction of rotation setting defines not only the direction of rotation of the connected DC
roller motors but also which of the two zones is the "downstream zone" and which is the
"upstream zone." In this way, the conveyor direction is also defined.
For clockwise direction of rotation, the left zone (IN1, MOT1) is the "upstream zone."
For counterclockwise direction of rotation, the right zone (IN2, MOT2) is the "upstream zone."
■
Switch position 0 ... 5: Clockwise direction of rotation (conveyor direction from left to right),
U
D
= High
■
Switch position 6 ... 9: Counterclockwise direction of rotation (conveyor direction from
right to left), U
D
= Low
S3: Operating mode
Depending on the application, you can select one of eight different operating modes for 1-zone
control or 2-zone control. For 1-zone control (Single Zone), the inactive zone synchronizes its
motor output with the active zone.
Switch setting
Ramp duration
Direction of rotation
0
0 ms
clockwise
1
500 ms
clockwise
2
1000 ms
clockwise
3
1500 ms
clockwise
4
3000 ms
clockwise
5
0 ms
counterclockwise
6
500 ms
counterclockwise
7
1000 ms
counterclockwise
8
1500 ms
counterclockwise
9
3000 ms
counterclockwise
Switch setting
Operation Mode
1-/2-zone operation
0
Standard ZPA
2-zone operation
1
Enhanced ZPA
2-zone operation
2
Standard ZPA
—
Single
Zone
1-zone operation
3
Enhanced ZPA
—
Single
Zone
1-zone operation
4
Transportation
1-zone operation and 2-zone operation
5
Long Zone
—
Single Zone
1-zone operation
6
Direct Control
1-zone operation and 2-zone operation
7
Direction Control
1-zone operation
100
75
50
25
200
400
600
800 1000
Speed [%]
Time [ms]
Speed 100%
Speed 60%
acceleration
time setting