Vibracon LVL-M2C
SI00113O-F
DO
CT
-0
56
0B
201
8-
10
1151
39
16
EN
Safety instructions:
Special conditions
Permitted ambient temperature range at the electronics housing: Observe the information in the
temperature tables.
• In the event of additional or alternative special varnishing on the housing or other metal parts:
– Observe the danger of electrostatic charging and discharge.
– Do not rub surfaces with a dry cloth.
Basic specification, feature housing, option PX
• Avoid electrostatic charging of the housing (e. g. friction, cleaning, maintenance, strong medium
flow).
Basic specification, feature housing, option AX
• Avoid sparks caused by impact and friction.
Gas group IIC
• A probe coated with non-conductive material can be used if avoiding electrostatic charging of the
probe (e. g. through friction, cleaning, maintenance, strong medium flow). Marked with warning
sign: “Avoid electrostatic charging”.
Safety instructions:
Installation
Basic specification, feature electrical connection, options SI, N1, N2
Figure 1
A
Zone 1
1
Tank; Zone 0
2
Electronic insert
3
Housing
4
Basic specification, feature electrical connection, options SI, N1, N2: associated intrinsically safe power supply units
2
3
A
1
4
– +