7. Set-up and maintenance

7.1  Functional testing

The safety function of the safety components must be tested. The 

following conditions must be previously checked and met:

1. Fitting of the sensor and the actuator.

2. Fitting and integrity of the power cable.

3.  The system is free of dirt and soiling (in particular metal chips).

7.2  Maintenance

In the case of correct installation and adequate use, the safety 

switchgear features maintenance-free functionality.

A regular visual inspection and functional test, including the following 

steps, is recommended:

1. Check the safety function

2.  Check the fixing and integrity of the safety switchgear, the actuator

and the cable

3. Remove possible metal chips.

Measures must be taken to protect against manipulation or 

against the bypassing of safety device, for example, using 

an extra actuator.

Damaged or defective components must be replaced.

8. Disassembly and disposal

8.1  Disassembly

The safety switchgear must be disassembled in a de-energised 

condition only.

8.2  Disposal

The safety switchgear must be disposed of in an appropriate manner in 

accordance with the national prescriptions and legislations.

Содержание schmersal RSS260 AS

Страница 1: ...responsibility of the manufacturer of a machine or plant to ensure the correct functionality of the entire machine or plant The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description Content 1 About this doc...

Страница 2: ...ronic safety sensor is designed for application in safety circuits and is used for monitoring the position of movable safety guards In this application the safety sensor monitors the position of hinged sliding or removable safety guards by means of the coded electronic actuator The safety function consists of safely switching off the code transmission when the safety guard is opened and maintainin...

Страница 3: ...essly approved by K A Schmersal GmbH Co KG could void the user s authority to operate the equipment L émetteur récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d Innovation Sciences et Développement économique Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 L appareil ne doit pas produire de bro...

Страница 4: ... the yellow LED signals the actuator detection the flashing of the yellow LED after a delay signals that the safety sensor is actuated in the hysteresis area Recommended Adjustment Align the safety sensor and actuator at a distance of 0 5 x sao The correct functionality of both safety channels must be checked by means of the connected safety monitoring module 3 5 Dimensions All measurements in mm ...

Страница 5: ...varying SaW code of a Safety at Work slave are evaluated through an OR operation with 4 inputs in the control system 5 4 Actuator teaching actuator detection Safety sensors with standard coding are ready to use upon delivery Individually coded safety sensors and actuators will require the following teach in procedure 1 Switch the safety sensor s voltage supply off and back on 2 Introduce the actua...

Страница 6: ...Off 1 static 0 Internal device error periphery error red green flashing Flashes 1 1 static 0 AS i error slave address 0 or communication error red depending on the condition 0 static 0 1 refer to flash code Table 2 Error messages flash codes yellow LED Flash codes yellow Designation Autonomous switch off after Error cause 4 flash pulses Ambient temperature high 0 min Ambient temperature too high T...

Страница 7: ...nctionality A regular visual inspection and functional test including the following steps is recommended 1 Check the safety function 2 Check the fixing and integrity of the safety switchgear the actuator and the cable 3 Remove possible metal chips Measures must be taken to protect against manipulation or against the bypassing of safety device for example using an extra actuator Damaged or defectiv...

Отзывы: