Source of error
Remedy
Door is detected
Reduce sensitivity, position sensing field further forward
LED does not light up
No voltage or device is damaged
Sensor responds to very slight influences
Door opens for no apparent reason
Increase immunity
Potentiometer is not functioning
Operation with RMS Remote control is switched on
No communication with RMS Remote control
Operation with DIP switch and potentiometer is turned on. Move
DIP switch 6 DOWN (OFF).
Access is disabled. Interrupt the operating voltage. After the power is
turned on again, configuration is possible for 30 minutes without code.
Check the Remote control batteries.
General specifications