Installation
2
0
2
0
-1
1
15
5.2
Mounting the Read Head
Mount the PCV... read head on the moving part of your equipment using the four screws on the
mounting adapter of the read head. Mount the read head in such a way that the lens with ring
light and camera module are aligned toward the code tape.
The stability of the mounting and the guidance of the moving system component must be such
that the field of the depth of focus of the read head is not exited during operation.
The distance between the read head and the code tape should be the same as the read dis-
tance of the read head.
Figure 5.4
Vertical alignment tolerance
Figure 5.5
Horizontal alignment tolerance
Optimum Read Distance (Z-Axis)
Model Number
Read Distance [mm]
Depth of Focus [mm]
PCV50*
50
±
25
PCV80*
80
±
15
PCV100*
100
±
20
PCV100*-...-6011
100
±
40
Read distance
Code reel
10°
10°
Read distance
10°