Reboot
The device can be restarted in this menu item.
7.3.3
Sensor Setup Menu Item
Language
The language can be set to German or English using this menu item.
Display mode
The display mode defines the display in normal mode when the menu is not
active. The display mode is set on a permanent basis. It is active following a
restart.
■
Display off
: The display goes dark as soon as the menu is exited.
■
Static logo
: The display shows the Fuchs logo. The logo can be
replaced with a custom bitmap file that will still be available after switching
the device on/off (saved in EEPROM). See the Ethernet protocol
description for details on programming.
■
Static text
: The display shows the text "Fuchs R2000". The text
can be replaced with custom text that will still be available after switching
the device off/on (saved in EEPROM). See the Ethernet protocol
description for details on programming.
■
Bargraph distance
: The display shows a bar graph indicating the
distance. The measured values in all directions are shown in the form of a
bar chart. The bars become smaller as the distance increases.
■
Bargraph reflector
: A bar is shown on the display at the point at which a
reflector is detected.
■
Bargraph echo
: The measured signal strength is shown in the form of a
graph on the display.
■
Application bitmap
: A custom bitmap file (24x252 bit) is shown on the
display that is no longer available after switching off the device (saved in
RAM). See the Ethernet protocol description for details on programming.
■
Application text
: Custom text is shown on the display that is no longer
available after switching off the device (saved in RAM). See the Ethernet
protocol description for details on programming.
Note!
Changing the IP Configuration
Changes to the IP configuration take effect only after a restart! The IP
configuration currently used by the device is displayed in the "Ethernet Info" menu
item. If these settings differ from the settings made under the "Ethernet Setup"
menu item, the device must be restarted.
Note!
The
Static logo
and
Static text
display modes are suitable for infrequent
changes to the logo and text data.
The
Application bitmap
and
Application text
display modes are suitable for
frequent changes to the logo and text data.