IDENT-I • IRI-KHD2-4.RX, IRI-KHA6-4.RX
Technical Data
Subject to reasonable modifications due to technical advances.
Copyright Fuchs, Printed in Germany
Fuchs Group • Tel.: Germany (06 21) 7 76-0 • USA (330) 4 25 35 55 • Singapore 7 79 90 91 • Internet http://www.pepperl-fuchs.com
Da
te
of
issue
27.
0
2
.2002
21
7
Technical Data
7.1
General specifications
The control interface unit is connected via the serial interface to a higher-order control
system (see figure 7.1).
The control interface unit receives the commands for reading the code carriers via this
interface.
Up to 4 read heads can be connected to the control interface unit. The read heads
can be queried individually or cyclically.
By means of DIP-switches three different operating modes can be selected at the
control interface unit: fixcode, 3964R protocol with RK512 interpreter or 3964R proto-
col without RK512 Interpreter.
With the "fixcode" operating mode, serial communication takes place via ASCII char-
acters. All commands consist of multiple ASCII characters.
The control interface unit supports the computer coupling procedure 3964R, which
was developed for programmable logic controllers; the commands are inserted into
the telegram frame of the procedure.
In addition, the RK512 interpreter can be used in combination with fetch telegrams.
Using the software IDENT 98 it is easy to communicate with the system. It describes
the system and the commissioning. A demonstration software is included in the scope
of delivery
.
Bild 7.1:
External view of the interface unit IVI-KHD2-4HRX/IVI-KHA6-4HRX
Sub-D-Stecker
DIP-Schalter
LED-Anzeige