IDENT-I • IRI-KHD2-4.RX, IRI-KHA6-4.RX
Operating control interface units using the 3964R protocol
Subject to reasonable modifications due to technical advances.
Copyright Fuchs, Printed in Germany
Fuchs Group • Tel.: Germany (06 21) 7 76-0 • USA (330) 4 25 35 55 • Singapore 7 79 90 91 • Internet http://www.pepperl-fuchs.com
Da
te
of
issue
27.
0
2
.2002
31
8.2
Command interpreter, systems for fixed code and read/write commands
8.2.1
Command structure
The mode commands described below behave in the same way as the corresponding
standard commands. For each mode command received, with the exception of the
RST command, the control interface unit responds with a message transmitting the
status of the control interface unit. The commands are transmitted to the control inter-
face unit in the form of data in a SEND message. The commands are encoded byte
by byte. The control interface unit acknowledges the commands with a further SEND
message, in which the status corresponding to the command is transmitted.
8.2.2
Mode commands
Example:
Correct transmission of the "Double-sided read" command
Description
Hex identifier
Parameter
Reset
01h
00h
Double-sided read
02h
00h
Byte 1
Byte 2
Mode command
Parameter
Byte 1
Byte 2
Mode command
Status/Error
Transmitted to the control interface unit:
’02 00'
Transmitted to the control system:
'02 00'
No message is transmitted in response to an RST command!
}
}
}
}