Operation
20
13-
10
13
quit QU
The running enhanced-buffered read or write commands are canceled.
configure interface CI
This command sets the timeout and the baud rate. The values are stored in a non-
volatile manner. A change always requires a reset to take effect.
The timeout indicates the amount of time, after which the device no longer waits
for more characters in a command. After the timeout runs through, the user gets
an error message. To deactivate the timeout, the time must be set to
“
0
”
.
The number of data bits is always 8. A parity bit is never used.
The following settings are possible:
The default values are a timeout of
“
0
”
and a baud rate of
“
38400
”
.
reset RS
This command sets the changed system settings, e.g. timeout and baud rate,
newly loaded from the non-volatile memory.
configuration store CS
If <Param> =
“
1
”
, the next command entered in this setting is stored in the non-
volatile memory. This command is also executed. After a reset it is automatically
active again.
<Param> =
“
0
”
deletes the stored command.
Command:
QU <DeviceNo> <CHCK> <ETX>
Response:
<Status> <DeviceNo> <CHCK> <ETX>
Command:
CI <DeviceNo> <Timeout>, <Baud> <CHCK> <ETX>
Response:
<Status> <DeviceNo> <CHCK> <ETX>
<Timeout>:
"0
“
...
“
100
”
(x 100 ms, timeout in 100-ms steps
<Baud>:
"1200
“
, "2400
“
, "4800
“
, "9600
“
, "19200
“
, "38400"
Command:
RS <DeviceNo> <CHCK> <ETX>
Response:
"2" <DeviceNo> <CHCK> <ETX>
Command:
CS <DeviceNo> <Param> <CHCK> <ETX>
Response:
<Status> <DeviceNo> <CHCK> <ETX>
Note!
Data collision
Only use the previous command if a single address is on the network.
Executing this command on more than one address will result in data collision.