Operation
20
13-
10
11
Standard read/write commands
Read data
Write data
Fixcode
5.3
System commands
Command description
Abbreviation
Page
single read words
SR
See "single read words SR" on page 14
enhanced buffered read
words
ER
See "enhanced buffered read words ER" on
page 14
Command description
Abbreviation
Page
single write words
SW
See "single write words SW" on page 14
enhanced buffered write
words
EW
See "enhanced buffered write words EW"
on page 15
Command description
Abbreviation
Page
single read fixcode
SF
See "single read fixcode SF" on page 15
enhanced buffered read
fixcode
EF
See "enhanced buffered read fixcode EF"
on page 15
Note!
Command structure
Since the IQT-F116-R4
M
-V1 features a device adress (= <DeviceNo>), you must
specify the device address within the commands.
For the IQT-F116-R4-V1 the device address is not applicable.
Examples
Command structure IQT-F116-R4-V1:
Command: <CommandCode><CommandParameters><CHCK><ETX>
Response: <Status><Data><CHCK><ETX>
Command structure IQT-F116-R4
M
-V1:
Command:
<CommandCode>
<DeviceNo>
<CommandParameters><CHCK><ETX>
Response: <Status>
<DeviceNo>
<Data><CHCK><ETX>
Optionally you can replace <CHK><ETX> with #<CR>.