IQT-F116-R4*-V1

Operation

Below you will find an overview of the memory setup and the memory capacities 

of the various read/write tags:

5.2

Command overview

The commands in the list are described in detail on the following pages.

System commands

Commands for IQT-F116-R4M-V1 only

Read-Only or 

Read/Write Tag

Access

Address Range 

<WordAddr>

Data Range 

<WordNum>

Memory 

Capacity in 

Bytes

ICODE_SLI

Read/write

0000 ... 001D

01 ... 1C

112

ICODE_SLI

Read-Only Code

-

-

8

TAGIT_HFI

Read/write

0000 ... 0039

01 ... 20

*

256

TAGIT_HFI

Read-Only Code

-

-

8

SRF_55V02P

Read/write

0000 ... 0037

01 ... 20

*

224

SRF_55V02P

Read-Only Code

-

-

8

SRF_55V10P

Read/write

0000 ... 00F7

01 ... 20

*

992

SRF_55V10P

Read-Only Code

-

-

8

Table 5.2

*

 The data range <WordNum> is limited either by the maximum memory 

capacity of the read/write tag, or by the memory bank of the read/write unit.

Command description

Abbreviation

Page

version

VE

See "version VE" on page 12

quit

QU

See "quit QU" on page 13

change tag

CT

See "change tag CT" on page 12

configure interface

CI

See "configure interface CI" on page 13

reset

RS

See "reset RS" on page 13

configuration store

CS

See "configuration store CS" on page 13

Command description

Abbreviation

Page

set device  address

SD

See "set device address SD" on page 14

get device address

GA

See "get device address GA" on page 14

Содержание IQT-F116-R4M-V1

Страница 1: ...IQT F116 R4 V1 IQT F116 R4M V1 Read write station 13 56 MHz FACTORY AUTOMATION MANUAL...

Страница 2: ...rms of Delivery for Products and Services of the Electrical Industry published by the Central Association of the Electrical Industry Zentralverband Elektrotechnik und Elektroindustrie ZVEI e V in its...

Страница 3: ...fic safety instructions 6 2 4 1 Read write station IQT F116 R4 V1 6 3 Product description 7 4 Installation 8 4 1 Storage and transport 8 4 2 Unpacking 8 4 3 Assembly and connection of the read write s...

Страница 4: ...entire range of device functions avoid faulty operation and the associated errors reduce costs from downtime and incidental repairs increase the effectiveness and operating efficiency of your plant S...

Страница 5: ...nufacturer from any liability If serious faults occur stop using the device Secure the device against inadvertent operation In the event of repairs return the device to your local Pepperl Fuchs repres...

Страница 6: ...wer source according to EN 60950 Note Disposal Electronic waste is hazardous waste When disposing of the equipment observe the current statutory requirements in the respective country of use as well a...

Страница 7: ...he read write station reads and writes at a frequency of 13 56 MHz The device is characterised particularly by its flat design with cable outlet and integrated M12 plug The housing is resistant to wel...

Страница 8: ...fy the supplier Retain the original packaging in case you have to store or ship the device again at a later date Should you have any questions please contact Pepperl Fuchs 4 3 Assembly and connection...

Страница 9: ...te range in which data can be written and modified as well as a protected memory in which the read only code is saved This read only code is issued by the manufacturer only once and can be read using...

Страница 10: ...Read write 0000 0037 01 20 224 SRF_55V02P Read Only Code 8 SRF_55V10P Read write 0000 00F7 01 20 992 SRF_55V10P Read Only Code 8 Table 5 2 The data range WordNum is limited either by the maximum memor...

Страница 11: ...mand description Abbreviation Page single read fixcode SF See single read fixcode SF on page 15 enhanced buffered read fixcode EF See enhanced buffered read fixcode EF on page 15 Note Command structur...

Страница 12: ...es are different Therefore the error message status 4 can only occur when a transponder is in front of the read write station Command VE DeviceNo CHCK ETX Response Status DeviceNo c P F IDENT I Type c...

Страница 13: ...reset RS This command sets the changed system settings e g timeout and baud rate newly loaded from the non volatile memory configuration store CS If Param 1 the next command entered in this setting i...

Страница 14: ...attempt is made until successful to read WordNum 32 bit words from the address WordAddr Only changing data is transferred via the interface When a data carrier leaves the read range the status 5 is ou...

Страница 15: ...us 0 is sent If there is no tag or a tag leaves then a status 5 is sent The command remains running Command EW DeviceNo WordAddr WordNum Data CHCK ETX Response Status DeviceNo CHCK ETX Note Data colli...

Страница 16: ...2 ASCII characters range from 01 to 1E ETX 1 ASCII character 03 Status 1 ASCII character SW No Application software number Tagtype 2 ASCII characters Timeout Interface timeout an error message is sen...

Страница 17: ...IQT F116 R4 V1 Operation 2013 10 17...

Страница 18: ...GmbH 68307 Mannheim Germany Tel 49 621 776 0 E mail info de pepperl fuchs com USA Headquarters Pepperl Fuchs Inc Twinsburg Ohio 44087 USA Tel 1 330 4253555 E mail sales us pepperl fuchs com Asia Paci...

Отзывы: