Functional Safety HiD2030(SK)

Planning

3.5

Useful Lifetime

Although a constant failure rate is assumed by the probabilistic estimation this only applies 

provided that the useful lifetime of components is not exceeded. Beyond this useful lifetime, 

the result of the probabilistic estimation is meaningless as the probability of failure significantly 

increases with time. The useful lifetime is highly dependent on the component itself 

and its operating conditions 

 temperature in particular. For example, electrolytic capacitors 

can be very sensitive to the operating temperature.
This assumption of a constant failure rate is based on the bathtub curve, 

which shows the typical behavior for electronic components.
Therefore it is obvious that failure calculation is only valid for components that have 

this constant domain and that the validity of the calculation is limited to the useful lifetime 

of each component.
It is assumed that early failures are detected to a huge percentage during the installation 

and therefore the assumption of a constant failure rate during the useful lifetime is valid.
However, according to IEC/EN 61508-2, a useful lifetime, based on general experience, 

should be assumed. Experience has shown that the useful lifetime often lies within a range 

period of about 8 to 12 years.
As noted in DIN EN 61508-2:2011 note N3, appropriate measures taken by the manufacturer 

and plant operator can extend the useful lifetime.
Our experience has shown that the useful lifetime of a Fuchs product can be higher 

if the ambient conditions support a long life time, for example if the ambient temperature 

is significantly below 60

°

C.

Please note that the useful lifetime refers to the (constant) failure rate of the device. 

The effective life time can be higher.
The estimated useful lifetime is greater than the warranty period prescribed by law 

or the manufacturer's guarantee period. However, this does not result in an extension 

of the warranty or guarantee services. Failure to reach the estimated useful lifetime is not 

a material defect.

Содержание HiD2030

Страница 1: ...ISO9001 2 Functional Safety SMART Transmitter Power Supply HiD2030 SK Manual...

Страница 2: ...ion as well as the supplementary clause Expanded reservation of proprietorship Worldwide Pepperl Fuchs Group Lilienthalstr 200 68307 Mannheim Germany Phone 49 621 776 0 E mail info de pepperl fuchs co...

Страница 3: ...ction 8 2 3 Interfaces 9 2 4 Marking 9 2 5 Standards and Directives for Functional Safety 9 3 Planning 10 3 1 System Structure 10 3 2 Assumptions 11 3 3 Safety Function and Safe State 12 3 4 Character...

Страница 4: ...Functional Safety HiD2030 SK Contents 4 2021 09...

Страница 5: ...g Dismounting Disposal The documentation consists of the following parts Present document Instruction manual Manual Datasheet Additionally the following parts may belong to the documentation if applic...

Страница 6: ...understood the instruction manual and the further documentation Intended Use The device is only approved for appropriate and intended use Ignoring these instructions will void any warranty and absolve...

Страница 7: ...displayed in descending order as follows Informative Symbols Action This symbol indicates a paragraph with instructions You are prompted to perform an action or a sequence of actions Danger This symbo...

Страница 8: ...an be monitored via a Fault Indication Board This device mounts on a HiD Termination Board HiD2030 The device provides a fully floating supply to power 2 wire SMART transmitters in the explosion hazar...

Страница 9: ...ing connections see datasheet Pepperl Fuchs Group Lilienthalstra e 200 68307 Mannheim Germany Internet www pepperl fuchs com HiD2030 HiD2030SK Up to SIL 2 Note If you design the safety loops in homoge...

Страница 10: ...lly the demand rate for this safety loop is assumed to be higher than once per year The relevant safety parameters to be verified are the PFH value Probability of dangerous Failure per Hour Fault reac...

Страница 11: ...ssumed For a higher average temperature of 60 C the failure rates must be multiplied by a factor of 2 5 based on experience A similar factor must be used if frequent temperature fluctuations are expec...

Страница 12: ...ltage outputs DIP switch settings for HiD2030 The outputs can be configured as 4 mA to 20 mA current output 1 V to 5 V voltage output DIP switch settings for HiD2030SK No user configuration available...

Страница 13: ...y function Transfer of the analog signals s 1 109 FIT dd 68 FIT du 51 9 FIT total safety function 1 1 No effect failures are not influencing the safety function and are therefore not included in the S...

Страница 14: ...umed that early failures are detected to a huge percentage during the installation and therefore the assumption of a constant failure rate during the useful lifetime is valid However according to IEC...

Страница 15: ...heck the safety function to ensure the expected output behavior 4 1 Configuration Configuring the Device The device is configured via DIP switches The DIP switches for setting the safety functions are...

Страница 16: ...the characteristic safety values provided See chapter 3 4 It is under the responsibility of the plant operator to define the type of proof test and the interval time period With the following instruc...

Страница 17: ...ice to the original settings Figure 5 1 Proof test set up for HiD2030 Set input value mA Mandatory measuring points Output value mA Output value V 20 0 20 0 0 4 5 0 0 1 12 0 12 0 0 4 3 0 0 1 4 0 4 0 0...

Страница 18: ...D2030SK HiD2030SK Termination Board 11 14 SL1 8a 7a 12 15 10a 9a SL2 1 4 5a 5b 7 7a 2 5 1a 1b 6 3b Fault 1a 1b 2a 2b 6b Zone 2 Div 2 Zone 0 1 2 Div 1 2 I II mA mA Multimeter mA 24 V DC Multimeter mA 2...

Страница 19: ...fect always replace the device with an original device Reporting Device Failure If you use the device in a safety loop according to IEC EN 61508 it is required to inform the device manufacturer about...

Страница 20: ...tion not part Probability of failure of components that are not in the safety loop total safety function Probability of failure of components that are in the safety loop HFT Hardware Fault Tolerance M...

Страница 21: ...Functional Safety HiD2030 SK Notes 2021 09 21...

Страница 22: ...Pepperl Fuchs Quality Download our latest policy here www pepperl fuchs com quality www pepperl fuchs com Pepperl Fuchs Subject to modifications Printed in Germany DOCT 7367...

Отзывы: